Calculation of intraprocedural hemodynamics with computational functional dynamic in mitral valve edge-to-edge repair

Abstract Background Hemodynamic outcomes in patients undergoing transcatheter edge-to-edge-repair of the mitral valve (M-TEER) are difficult to predict. Computational functional dynamic (CFD) is frequently used in biomedical engineering to simulate blood flow patterns under various conditions. The authors developed a standardized workflow for individualized analyses and investigated the hemodynamic of mitral regurgitation volumes and gradients by using CFD. Methods 20 patients from two high volume centers who suffered from severe mitral regurgitation (MR) and underwent full cycle cardiac computed tomography (CT) prior procedure were enrolled. Baseline computed tomography and intraprocedural data were analyzed. Based on the specific valve morphology, individualized CFD-simulations were performed to calculate MR volumes prior to intervention and estimate hemodynamics after M-TEER. Results CFD-analyses of 20 patients (mean age 80±4 years, 60% male) showed excellent correlation between baseline PISA method-based MR volumes (45±23ml) measured in transesophageal echocardiography (TEE) and CFD-based calculation (45±26ml; R=0.917; P<0.001) as well as between TEE-measured mean baseline effective regurgitant orifice area (EROA; 27±16mm²) and CFD-measured EROA (24±18mm²; R=0.869; P<0.001)). After device implantation, correlation between intraprocedural TEE-measured and CFD-estimated correlation for residual MR volumes (R=0.949; P<0.001) and EROA (R=0.841; P<0.001) remained robust. Post-interventional mean diastolic pressure gradient (TEE) was 3.6±2.8mmHg which was in close correlation with the CFD estimated gradient (3.0±1.8mmHg, R=0.905; P<0.001). Conclusions This is the first study to use a CFD-standardized workflow for predicting hemodynamic changes in patients undergoing M-TEER using data from two different centers. In the future, CFD-based analyses might serve as a key-diagnostic tool for predicting residual MR volumes and gradients for M-TEER-procedures.Comparison of TEE and CFD flow patternBland-Altman-Blots

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.184
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation of intraprocedural hemodynamics with computational functional dynamic in mitral valve edge-to-edge repair

Muhammed Gerçek, Kai Friedrichs, Volker Rudolph, Felix Rudolph et al.
1 links
European Heart Journal
Cardiac Valve Diseases and Treatments
article

Calculation of intraprocedural hemodynamics with computational functional dynamic in mitral valve edge-to-edge repair

Muhammed Gerçek, Kai Friedrichs, Volker Rudolph, Felix Rudolph, Mohammad Kassar, Hazem Omran, C Graeni, Fabien Praz, Tanja K. Rudolph, Johannes Kirchner
article en

Abstract

Abstract Background Hemodynamic outcomes in patients undergoing transcatheter edge-to-edge-repair of the mitral valve (M-TEER) are difficult to predict. Computational functional dynamic (CFD) is frequently used in biomedical engineering to simulate blood flow patterns under various conditions. The authors developed a standardized workflow for individualized analyses and investigated the hemodynamic of mitral regurgitation volumes and gradients by using CFD. Methods 20 patients from two high volume centers who suffered from severe mitral regurgitation (MR) and underwent full cycle cardiac computed tomography (CT) prior procedure were enrolled. Baseline computed tomography and intraprocedural data were analyzed. Based on the specific valve morphology, individualized CFD-simulations were performed to calculate MR volumes prior to intervention and estimate hemodynamics after M-TEER. Results CFD-analyses of 20 patients (mean age 80±4 years, 60% male) showed excellent correlation between baseline PISA method-based MR volumes (45±23ml) measured in transesophageal echocardiography (TEE) and CFD-based calculation (45±26ml; R=0.917; P<0.001) as well as between TEE-measured mean baseline effective regurgitant orifice area (EROA; 27±16mm²) and CFD-measured EROA (24±18mm²; R=0.869; P<0.001)). After device implantation, correlation between intraprocedural TEE-measured and CFD-estimated correlation for residual MR volumes (R=0.949; P<0.001) and EROA (R=0.841; P<0.001) remained robust. Post-interventional mean diastolic pressure gradient (TEE) was 3.6±2.8mmHg which was in close correlation with the CFD estimated gradient (3.0±1.8mmHg, R=0.905; P<0.001). Conclusions This is the first study to use a CFD-standardized workflow for predicting hemodynamic changes in patients undergoing M-TEER using data from two different centers. In the future, CFD-based analyses might serve as a key-diagnostic tool for predicting residual MR volumes and gradients for M-TEER-procedures.Comparison of TEE and CFD flow patternBland-Altman-Blots

European Heart JournalVol. 45(Supplement_1)
Heart and Diabetes Center North Rhine-Westphalia (DE), University Hospital of Bern (CH)
Openalex Percentile: Top 66%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.