Evaluating the potential of hydrophilic interaction liquid chromatography for collagen peptide mapping analysis

This study presents a systematic approach for developing an innovative hydrophilic interaction liquid chromatography (HILIC) method for collagen peptide mapping analysis. The predominant post-translational modification (PTM) of collagen, proline hydroxylation, introduces polar hydroxyl groups throughout the collagen sequence, making HILIC a promising alternative to classical reversed-phase liquid chromatography (RPLC) approaches. This study employs sixteen model peptides, selected from in silico predicted tryptic peptides with zero missed cleavages and representing diverse physicochemical properties and structural motifs of collagen. The peptides were used as standards to conduct detailed chromatographic evaluation. Various HILIC stationary phases and mobile phases were systematically examined to identify optimal separation conditions for collagen peptides, contributing to a better understanding of peptide behavior in HILIC. The study also explores the effects of sample diluent and injection mode, comparing classical injection with the Performance Optimizing Injection Sequence (POISe), to determine their impact on HILIC performance. Introducing a plug of weak solvent (acetonitrile) prior to sample injection, effectively mitigates the mismatch in eluent strength between the fully aqueous sample diluent (resulting from tryptic digestion) and the mobile phase, addressing issues of peak distortion. Different injection volumes (from 0.5 to 8 µL) and acetonitrile ratios (1:1, 1:2, 1:5 and 1:10) were tested to optimize sample injection and increase sensitivity of collagen tryptic peptides. Following method optimization, HILIC was coupled with mass spectrometry (MS) to evaluate its effectiveness in analyzing collagen-digested samples. This evaluation included the assessment of peptide sequence coverage and the method ability to identify hydroxylation patterns, thereby demonstrating its potential for detailed peptide analysis.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2024-10-28
DOI
https://doi.org/10.1016/j.chroma.2024.465473
Citations
5
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
1.20

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the potential of hydrophilic interaction liquid chromatography for collagen peptide mapping analysis

Davy Guillarme, Gabriella Massolini, Caterina Temporini, Sara Tengattini et al.
5 citations
Journal of Chromatography A
Analytical Chemistry and Chromatography
1.20
article

Evaluating the potential of hydrophilic interaction liquid chromatography for collagen peptide mapping analysis

Davy Guillarme, Gabriella Massolini, Caterina Temporini, Sara Tengattini, Valentina D’Atri, Martina Lioi, Simona Daly
article en
5 citations

Abstract

This study presents a systematic approach for developing an innovative hydrophilic interaction liquid chromatography (HILIC) method for collagen peptide mapping analysis. The predominant post-translational modification (PTM) of collagen, proline hydroxylation, introduces polar hydroxyl groups throughout the collagen sequence, making HILIC a promising alternative to classical reversed-phase liquid chromatography (RPLC) approaches. This study employs sixteen model peptides, selected from in silico predicted tryptic peptides with zero missed cleavages and representing diverse physicochemical properties and structural motifs of collagen. The peptides were used as standards to conduct detailed chromatographic evaluation. Various HILIC stationary phases and mobile phases were systematically examined to identify optimal separation conditions for collagen peptides, contributing to a better understanding of peptide behavior in HILIC. The study also explores the effects of sample diluent and injection mode, comparing classical injection with the Performance Optimizing Injection Sequence (POISe), to determine their impact on HILIC performance. Introducing a plug of weak solvent (acetonitrile) prior to sample injection, effectively mitigates the mismatch in eluent strength between the fully aqueous sample diluent (resulting from tryptic digestion) and the mobile phase, addressing issues of peak distortion. Different injection volumes (from 0.5 to 8 µL) and acetonitrile ratios (1:1, 1:2, 1:5 and 1:10) were tested to optimize sample injection and increase sensitivity of collagen tryptic peptides. Following method optimization, HILIC was coupled with mass spectrometry (MS) to evaluate its effectiveness in analyzing collagen-digested samples. This evaluation included the assessment of peptide sequence coverage and the method ability to identify hydroxylation patterns, thereby demonstrating its potential for detailed peptide analysis.

Journal of Chromatography AVol. 1738
University of Geneva (CH), University of Pavia (IT), Ono Pharmaceutical (United States) (US), Lesaffre (France) (FR)
Ministero dell'Università e della Ricerca
Openalex Percentile: Top 23%
Analytical Chemistry and Chromatography
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.