Excluding significant coronary artery disease in patients planned for TAVR using CT: Diagnostic accuracy of newest generation dual source photon counting scanner compared to coronary angiography

Abstract Introduction Patients with significant aortic stenosis routinely undergo CT for evaluation of the aortic root prior to interventional aortic valve replacement (TAVR). Assessment of CAD is usually performed by invasive coronary angiography. We assessed the diagnostic accuracy of the latest generation dual source photon counting scanner for exclusion of relevant CAD in a contemporary TAVR cohort. Methods Patients referred for cardiac CT prior to transcatheter aortic valve implantation were screened for inclusion this analysis. All cardiac CT exams were performed by dual source photon counting scanner (NAEOTOM alpha, Siemens healthineers, Germany). CT acquisitions were performed using retrospectively triggered spiral acquisition (30-70% of the cardiac cycle) without ultra-high resolution. For each patient, several reconstructions were rendered (thin slice reconstruction with 0.4 mm slice thickness: best diastolic phase, best systolic phase, 200-350 ms folllowing R-wave in 50 ms intervals as well as 0.6 mm slice thickness multiphase reconstruction 0-90% of the cardiac cycle in 10 % increments). Assessment of significant CAD was performed in CT and invasive angiography on a per-vessel analysis and a per-patient analysis using 2 thresholds: ≥ 50% stenosis and ≥ 70% stenosis. Assessment of stenoses in CT was performed using multiplanar reconstructions (MPR) and curved MPR and only in vessels > 1.5mm diameter. Assessment of stenosis in invasive angiography was performed using the projection with the most relevant lumen reduction. Image quality in CT was assessed on a likert scale from 1 to 4 (1=excellent, 2=minor artifacts, 3=major artifacts still assessable, 4=non-assessable). Results In this analysis 31 consecutive patients were included (mean age 79.5y, 64.5% males, 35.5% females). Mean heart rate was 66.5 bpm and 19% were in atrial fibrillation during CT acquisition. Mean image quality was 1.4. 13 Patients had no relevant CAD (stenosis ≥50%) in invasive angiography and in 18 patients at least 1 vessel was deemed to have ≥ 50% stenosis in invasive angiography. On a per vessel analysis, sensitivity, specificity and accuracy of cardiac CT to exclude stenoses using 50% and 70% thresholds were 98%, 93% and 94% vs. 97%, 93% and 94%, respectively. Negative likelihood ratio was 0.02 vs. 0.03 respectively. On a per-patient level, sensitivity and specificity were 100%. Out of 31 patients, only 2 vessels in 2 patients were deemed non-assessable. 3 patients with previous PCI as well as 3 patients with previous CABG were included in this analysis. Only 1 false negative vessel was reported in a very distal LAD segment. Conclusion Using newest generation dual source CT with photon counting, CT allowed highly reliable diagnostic workup regarding the presence of CAD in this TAVR cohort. The use of CT to assess CAD in TAVR patients seems clinically feasible especially in patients without previous percutaneous revascularisation.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.211
Citations
2
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Excluding significant coronary artery disease in patients planned for TAVR using CT: Diagnostic accuracy of newest generation dual source photon counting scanner compared to coronary angiography

M Marwan, Stephan Achenbach, T. Zuhair Kassem
2 citations
European Heart Journal
Advanced X-ray and CT Imaging
0.37
article

Excluding significant coronary artery disease in patients planned for TAVR using CT: Diagnostic accuracy of newest generation dual source photon counting scanner compared to coronary angiography

M Marwan, Stephan Achenbach, T. Zuhair Kassem
article en
2 citations

Abstract

Abstract Introduction Patients with significant aortic stenosis routinely undergo CT for evaluation of the aortic root prior to interventional aortic valve replacement (TAVR). Assessment of CAD is usually performed by invasive coronary angiography. We assessed the diagnostic accuracy of the latest generation dual source photon counting scanner for exclusion of relevant CAD in a contemporary TAVR cohort. Methods Patients referred for cardiac CT prior to transcatheter aortic valve implantation were screened for inclusion this analysis. All cardiac CT exams were performed by dual source photon counting scanner (NAEOTOM alpha, Siemens healthineers, Germany). CT acquisitions were performed using retrospectively triggered spiral acquisition (30-70% of the cardiac cycle) without ultra-high resolution. For each patient, several reconstructions were rendered (thin slice reconstruction with 0.4 mm slice thickness: best diastolic phase, best systolic phase, 200-350 ms folllowing R-wave in 50 ms intervals as well as 0.6 mm slice thickness multiphase reconstruction 0-90% of the cardiac cycle in 10 % increments). Assessment of significant CAD was performed in CT and invasive angiography on a per-vessel analysis and a per-patient analysis using 2 thresholds: ≥ 50% stenosis and ≥ 70% stenosis. Assessment of stenoses in CT was performed using multiplanar reconstructions (MPR) and curved MPR and only in vessels > 1.5mm diameter. Assessment of stenosis in invasive angiography was performed using the projection with the most relevant lumen reduction. Image quality in CT was assessed on a likert scale from 1 to 4 (1=excellent, 2=minor artifacts, 3=major artifacts still assessable, 4=non-assessable). Results In this analysis 31 consecutive patients were included (mean age 79.5y, 64.5% males, 35.5% females). Mean heart rate was 66.5 bpm and 19% were in atrial fibrillation during CT acquisition. Mean image quality was 1.4. 13 Patients had no relevant CAD (stenosis ≥50%) in invasive angiography and in 18 patients at least 1 vessel was deemed to have ≥ 50% stenosis in invasive angiography. On a per vessel analysis, sensitivity, specificity and accuracy of cardiac CT to exclude stenoses using 50% and 70% thresholds were 98%, 93% and 94% vs. 97%, 93% and 94%, respectively. Negative likelihood ratio was 0.02 vs. 0.03 respectively. On a per-patient level, sensitivity and specificity were 100%. Out of 31 patients, only 2 vessels in 2 patients were deemed non-assessable. 3 patients with previous PCI as well as 3 patients with previous CABG were included in this analysis. Only 1 false negative vessel was reported in a very distal LAD segment. Conclusion Using newest generation dual source CT with photon counting, CT allowed highly reliable diagnostic workup regarding the presence of CAD in this TAVR cohort. The use of CT to assess CAD in TAVR patients seems clinically feasible especially in patients without previous percutaneous revascularisation.

European Heart JournalVol. 45(Supplement_1)
Universitätsklinikum Erlangen (DE)
Openalex Percentile: Top 43%
Advanced X-ray and CT Imaging
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.