dPdT >1200ms predicts greater and sustained drop in ejection fraction post mitral TEER

Abstract Background The maximum rate of left ventricular pressure rise (dP/dTmax) using a CW Doppler from a mitral regurgitation (MR) curve is a simple technique which can estimate myocardial contractility, with "normal" values >1200ms. This technique has not been applied to patients undergoing mitral transcatheter edge-to-edge repairs (M-TEER). Purpose Assess if dP/dT can predict post-procedural ejection fraction (EF). Methods A retrospective review of all M-TEER's performed from January 2011 – February 2023 at a single cardiac centre with an adequate MR CW Doppler to calculate the dP/dT as well as a subsequent TTE at the institution were included. An early TTE (performed day 1-50, average 34.9) and late TTE (goal 1 year, average 354 days) were recorded. Results A total of 155 M-TEER procedures were performed; 66 for degenerative MR (DMR), 11 for atrial functional MR (AFMR) and 78 for ventricular functional MR (VFMR). Baseline characteristics: overall EF 47.9% (DMR 61%, AFMR 52% and VFMR 32%). Age DMR 75.8y, AMFR 78.9y, VFMR 75.6y), overall 31.6% female (DMR 34.6%, AFMR 45.5%, VFMR 25.8%). Surprisingly the DMR cohort demonstrated a significant drop in EF post M-TEER of 5.1% (p<0.001, figure 1). This was most marked in the group with "normal" dP/dT of >1200ms (figure 2, DMR EF drop 7.8% p<0.001). This cohort remained at the new, lower value on follow up (figure 2). The EF in the VFMR remained severely impaired despite M-TEER (figure 1). There was no significant difference between EF pre or early post (p= 0.86). When divided into groups according to baseline dP/dT. The greatest drop in EF was again seen with an apparently normal dP/dT of >1200ms (figure 2). Conclusion "Normal" dP/dT of >1200ms in patients undergoing M-TEER is likely a marker of hyper-contractile LV function as a compensatory mechanism, and may predict a greater fall in EF post correction of MR.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.169
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

dPdT >1200ms predicts greater and sustained drop in ejection fraction post mitral TEER

Mark Higgins, K. Lander, O. Raffel, D. Murdoch et al.
European Heart Journal
ECG Monitoring and Analysis
article

dPdT >1200ms predicts greater and sustained drop in ejection fraction post mitral TEER

Mark Higgins, K. Lander, O. Raffel, D. Murdoch, G. Scalia, D. Walters, K C Lau
article en

Abstract

Abstract Background The maximum rate of left ventricular pressure rise (dP/dTmax) using a CW Doppler from a mitral regurgitation (MR) curve is a simple technique which can estimate myocardial contractility, with "normal" values >1200ms. This technique has not been applied to patients undergoing mitral transcatheter edge-to-edge repairs (M-TEER). Purpose Assess if dP/dT can predict post-procedural ejection fraction (EF). Methods A retrospective review of all M-TEER's performed from January 2011 – February 2023 at a single cardiac centre with an adequate MR CW Doppler to calculate the dP/dT as well as a subsequent TTE at the institution were included. An early TTE (performed day 1-50, average 34.9) and late TTE (goal 1 year, average 354 days) were recorded. Results A total of 155 M-TEER procedures were performed; 66 for degenerative MR (DMR), 11 for atrial functional MR (AFMR) and 78 for ventricular functional MR (VFMR). Baseline characteristics: overall EF 47.9% (DMR 61%, AFMR 52% and VFMR 32%). Age DMR 75.8y, AMFR 78.9y, VFMR 75.6y), overall 31.6% female (DMR 34.6%, AFMR 45.5%, VFMR 25.8%). Surprisingly the DMR cohort demonstrated a significant drop in EF post M-TEER of 5.1% (p<0.001, figure 1). This was most marked in the group with "normal" dP/dT of >1200ms (figure 2, DMR EF drop 7.8% p<0.001). This cohort remained at the new, lower value on follow up (figure 2). The EF in the VFMR remained severely impaired despite M-TEER (figure 1). There was no significant difference between EF pre or early post (p= 0.86). When divided into groups according to baseline dP/dT. The greatest drop in EF was again seen with an apparently normal dP/dT of >1200ms (figure 2). Conclusion "Normal" dP/dT of >1200ms in patients undergoing M-TEER is likely a marker of hyper-contractile LV function as a compensatory mechanism, and may predict a greater fall in EF post correction of MR.

European Heart JournalVol. 45(Supplement_1)
Prince Charles Hospital (GB)
Openalex Percentile: Top 67%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.