Abstract Introduction Hand-held Ultrasound devices (HHUD) are increasingly used in routine clinical practice, although until recently they did not have continuous Doppler. There is no evidence on the usefulness of an HHUD for the assessment of aortic stenosis (AS) in real life. Objective To validate the use of a new HHUD device in a real-life scenario. Material and methods Observational, single-center and prospective study, including patients diagnosed with AS with a previous standard echocardiography. Patients were randomly recruited from a tertiary cardiac imaging laboratory. Immediately after the reference echocardiography performed by an imaging expert, a Cardiology trainee with ASE level II repeated the study blindly with an HHUD. Agreement between the two tests was evaluated by measuring the mean aortic valve gradient (mAG). An intraclass correlation coefficient (ICC) test, linear regression, and Bland-Altman test were performed to compare the two methods. Results 101 patients were recruited. The reference test calculated a mAG of 29 mmHg (19.8 - 42.2) versus a mAG of 27.2 mmHg (16.2 - 43.9) in HHUD. The statistical analysis showed a good correlation between both tests (ICC: 0.87 (95% CI: 0.79 -0.94) and r=0.89 (95% CI: 0.85-0.94) (Figure). The Bland-Altman test showed a non-significant underestimation (1.61 ± 0.9 mmHg; p= 0.09). The HHUD classified 29 cases as severe or major AS compared to 31 in the reference test (kappa= 0.81; 95% CI: 0.68 - 0.94). The HHUD showed an excellent agreement for classification of AS in at least severe AS grade. The kappa analysis had a value of 0.81 (95% CI 0.68 – 0.94) with a global agreement of 92.1%. The positive predictive value was 89.6%. The negative predictive value was 93.1%. Sensitivity and specificity were 83.8% and 95.7%. The rest of the variables evaluated showed poorer agreement. In those patients with obesity, worse acoustic window, atrial fibrillation and critical AS, the agreement was worse. Conclusions The new HHUD evaluated by an operator with limited experience showed good agreement with the reference echocardiographic device in determining the mean aortic gradient.Central picture

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.121
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a hand-held ultrasound device in the evaluation of aortic stenosis

Marta González, J M Cuesta Cosgaya, R Perez Barquin, N Ruíz et al.
European Heart Journal
Cardiac Valve Diseases and Treatments
article

Validation of a hand-held ultrasound device in the evaluation of aortic stenosis

Marta González, J M Cuesta Cosgaya, R Perez Barquin, N Ruíz, J Zubiaur Zamacola, Cristina Ruisánchez Villar, David Serrano, José A. Vázquez de Prada, Francisco González Vílchez, Antonello Castro, José M. de la Torre, C Coroas, Lucía Muñoz Prejigueiro, L Abia, H Alarcos
article en

Abstract

Abstract Introduction Hand-held Ultrasound devices (HHUD) are increasingly used in routine clinical practice, although until recently they did not have continuous Doppler. There is no evidence on the usefulness of an HHUD for the assessment of aortic stenosis (AS) in real life. Objective To validate the use of a new HHUD device in a real-life scenario. Material and methods Observational, single-center and prospective study, including patients diagnosed with AS with a previous standard echocardiography. Patients were randomly recruited from a tertiary cardiac imaging laboratory. Immediately after the reference echocardiography performed by an imaging expert, a Cardiology trainee with ASE level II repeated the study blindly with an HHUD. Agreement between the two tests was evaluated by measuring the mean aortic valve gradient (mAG). An intraclass correlation coefficient (ICC) test, linear regression, and Bland-Altman test were performed to compare the two methods. Results 101 patients were recruited. The reference test calculated a mAG of 29 mmHg (19.8 - 42.2) versus a mAG of 27.2 mmHg (16.2 - 43.9) in HHUD. The statistical analysis showed a good correlation between both tests (ICC: 0.87 (95% CI: 0.79 -0.94) and r=0.89 (95% CI: 0.85-0.94) (Figure). The Bland-Altman test showed a non-significant underestimation (1.61 ± 0.9 mmHg; p= 0.09). The HHUD classified 29 cases as severe or major AS compared to 31 in the reference test (kappa= 0.81; 95% CI: 0.68 - 0.94). The HHUD showed an excellent agreement for classification of AS in at least severe AS grade. The kappa analysis had a value of 0.81 (95% CI 0.68 – 0.94) with a global agreement of 92.1%. The positive predictive value was 89.6%. The negative predictive value was 93.1%. Sensitivity and specificity were 83.8% and 95.7%. The rest of the variables evaluated showed poorer agreement. In those patients with obesity, worse acoustic window, atrial fibrillation and critical AS, the agreement was worse. Conclusions The new HHUD evaluated by an operator with limited experience showed good agreement with the reference echocardiographic device in determining the mean aortic gradient.Central picture

European Heart JournalVol. 45(Supplement_1)
Marqués de Valdecilla University Hospital (ES)
Instituto de Investigación Marqués de Valdecilla
Openalex Percentile: Top 67%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.