Cardiac amyloidosis: a texture issue. a proof of concept study on quantification of granular sparkling in patients with transthyretin-related cardiac amyloidosis using radiomics and granulometry

Abstract Background Granular sparkling is a well-known echocardiographic feature found in patients with transthyretin-related cardiac amyloidosis (ATTR-CA). However, there is no objective technique for quantifying this feature, which therefore remains a qualitative, elusive and ultimately unreliable imaging characteristic. Recent evidence suggests that radiomics and, in particular, ultrasonomics could play an important role in the non-invasive tissue characterization of cardiomyopathies through the study of specific myocardial texture features. Purpose The aim of this study is to statistically and geometrically characterize granular sparkling as a volume-independent texture property of the myocardium in patients with ATTR-CA. Methods We retrospectively collected echocardiogram video-clips in parasternal long axis (PLAX) and 4-chamber (4CH) views of 229 patients with ATTR-CA, and 224 age- and gender-matched hypertensive patients without any known cardiac disease. From each video-clip, one end-diastole frame was extracted and annotated by an expert to identify a region-of-interest (ROI) within the interventricular septum. Left ventricle chamber masks were also extracted, and used as a brightness reference to enforce invariance w.r.t. the settings of the specific ultrasound system (Fig. 1). Because many established radiomic textural features are heavily volume-confounded, we analyzed the ROI texture by extracting a subset of volume-invariant radiomic features (i.e. ROI-independent), as well as morphological granulometry features. We then fitted a logistic regression classifier to discriminate between ATTR-CA and controls based on the computed textural features. Results 94 radiomic features were identified, of which 73 were volume-invariant. The texture-based classifier predicted the diagnosis with a cross-validated accuracy of 91%, a specificity of 90% and a sensitivity of 92% by utilizing 73 volume-invariant radiomic features on both PLAX and 4CH views (Fig. 2). The addition of granulometry and the further addition of 11 volume-confounded features and 9 shape features to the model did not significantly enhance its discriminative performance (Fig. 2). The top 10 volume-invariant discriminative features were largely consistent in PLAX and 4CH views (Fig. 2), with variables descriptive of greater heterogeneity (such as glszm_ZoneEntropy and glszm_RunEnNtropy) and a higher spatial rate of change (such as ngtdm_Complexity) in the texture of ATTR-CA frames as compared to control frames. Conclusions Our results confirm the ability of radiomics in detecting subtle differences in the myocardial texture of echocardiographic images between patients with ATTR-CA and hypertensive controls. High levels of accuracy are obtained with a purely texture-based, volume-independent set of features. These findings suggest that the diagnosis of ATTR-CA could be simplified and made earlier using a statistical model based on the extraction of radiomic features.Figure 1Figure 2

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.153
Primary Topic
Parathyroid Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac amyloidosis: a texture issue. a proof of concept study on quantification of granular sparkling in patients with transthyretin-related cardiac amyloidosis using radiomics and granulometry

Carlotta Mazzoni, Pier Filippo Vianello, Giulia Elena Mandoli, Maria Pia Sormani et al.
European Heart Journal
Parathyroid Disorders and Treatments
article

Cardiac amyloidosis: a texture issue. a proof of concept study on quantification of granular sparkling in patients with transthyretin-related cardiac amyloidosis using radiomics and granulometry

Carlotta Mazzoni, Pier Filippo Vianello, Giulia Elena Mandoli, Maria Pia Sormani, Noemi Montobbio, Cristina Campi, Marco Canepa, Italo Porto, Francesco Cappelli, Matteo Cameli, Sara Mori, Margherita Zanoletti, Francesca Rubina Ginetti
article en

Abstract

Abstract Background Granular sparkling is a well-known echocardiographic feature found in patients with transthyretin-related cardiac amyloidosis (ATTR-CA). However, there is no objective technique for quantifying this feature, which therefore remains a qualitative, elusive and ultimately unreliable imaging characteristic. Recent evidence suggests that radiomics and, in particular, ultrasonomics could play an important role in the non-invasive tissue characterization of cardiomyopathies through the study of specific myocardial texture features. Purpose The aim of this study is to statistically and geometrically characterize granular sparkling as a volume-independent texture property of the myocardium in patients with ATTR-CA. Methods We retrospectively collected echocardiogram video-clips in parasternal long axis (PLAX) and 4-chamber (4CH) views of 229 patients with ATTR-CA, and 224 age- and gender-matched hypertensive patients without any known cardiac disease. From each video-clip, one end-diastole frame was extracted and annotated by an expert to identify a region-of-interest (ROI) within the interventricular septum. Left ventricle chamber masks were also extracted, and used as a brightness reference to enforce invariance w.r.t. the settings of the specific ultrasound system (Fig. 1). Because many established radiomic textural features are heavily volume-confounded, we analyzed the ROI texture by extracting a subset of volume-invariant radiomic features (i.e. ROI-independent), as well as morphological granulometry features. We then fitted a logistic regression classifier to discriminate between ATTR-CA and controls based on the computed textural features. Results 94 radiomic features were identified, of which 73 were volume-invariant. The texture-based classifier predicted the diagnosis with a cross-validated accuracy of 91%, a specificity of 90% and a sensitivity of 92% by utilizing 73 volume-invariant radiomic features on both PLAX and 4CH views (Fig. 2). The addition of granulometry and the further addition of 11 volume-confounded features and 9 shape features to the model did not significantly enhance its discriminative performance (Fig. 2). The top 10 volume-invariant discriminative features were largely consistent in PLAX and 4CH views (Fig. 2), with variables descriptive of greater heterogeneity (such as glszm_ZoneEntropy and glszm_RunEnNtropy) and a higher spatial rate of change (such as ngtdm_Complexity) in the texture of ATTR-CA frames as compared to control frames. Conclusions Our results confirm the ability of radiomics in detecting subtle differences in the myocardial texture of echocardiographic images between patients with ATTR-CA and hypertensive controls. High levels of accuracy are obtained with a purely texture-based, volume-independent set of features. These findings suggest that the diagnosis of ATTR-CA could be simplified and made earlier using a statistical model based on the extraction of radiomic features.Figure 1Figure 2

European Heart JournalVol. 45(Supplement_1)
University of Siena (IT), Department of Medical Sciences (BY), Ospedale Policlinico San Martino (IT), University of Florence (IT), University of Genoa (IT)
Reduced inequalities
Openalex Percentile: Top 76%
Parathyroid Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.