Fastidious adherence to 0/1-hour high-sensitivity troponin T testing reduces emergency department length of stay in patients presenting with suspected acute coronary syndromes

Abstract Background High-sensitivity cardiac troponins (hs-cTn) are key clinical biomarkers in patients presenting with suspected acute coronary syndromes (ACS) to Emergency Departments (EDs). They have facilitated rapid 0h/1h troponin testing protocols, leading to safe, effective, and efficient triage of patients. However, early distinction of myocardial infarction (MI), which has a reported frequency of less than 10% in most cohorts, from the apparently stable hs-cTn elevations of chronic myocardial injury (CMI) remains a challenge. Often CMI patients require confirmation by further testing and observation, prolonging patient length of stay. Further, reliably obtaining serial hs-cTn samples at 60-minutes in a busy ED setting may be difficult. A potential explanation for only 5-6% of Australian sites adopting 0h/1h hs-cTn testing. Methods and Results We undertook a case-control study between March and August 2023 among patients with suspected ACS presenting to Liverpool Hospital ED (Sydney, Australia). 185 patients (cases) underwent hs-cTnT sampling at 30- and 60-minutes (± 5 minutes) after baseline. Diagnosis of MI was made in 8.6%, 35.7% were placed into a further observation group and MI ruled-out in 55.7%. The latter two groups were matched to 169 patients (controls) who received ‘usual’ care, which was a 0h/1h hs-cTnT testing protocol. The case and control arms were matched by age, gender, time from symptom onset and main presenting symptom. Control patients had a median sampling interval of 118 [85 to 174] minutes, rather 60 minutes as the protocol directs. When comparing the paired differences between the case and control arms, there was a mean reduction in length of stay of 104 (95% CI: 41 to 186, P = 0.01) and 47 (95% CI: 11 to 84, P = 0.01) minutes, for the observation and rule-out MI groups respectively. The figure shows the distribution of lengths of stay by group. Among the rule-out group, Wilcoxon signed rank test indicated the control arm had a longer median length of stay of 6.3 [5.1 to 8.4] hours, compared to 5.0 [4.5 to 7.1] hours in the case arm (P=0.005). Similarly, in the further observation group, control patients also had a longer median length of stay of 9.2 [6.9 to 10.4] hours compared to case patients of 8.1 [5.1 to 10.3] hours (P = 0.009). At 30-days, ED representation rates were 10.7% in controls and 8.3% in cases, rehospitalisation 3.6% in controls and 5.3% in cases, cardiac death 0% in both arms and non-cardiac death 1% in both arms. There were no differences in event rates between each arm (P > 0.05). Conclusion Accurate 0h/1h hs-cTnT testing reduces patient length of stay in ED and offers more personalised prediction of MI risk. The importance of adherence to protocol-directed sampling times is clear, where further studies are required regarding routine implementation in a busy ED setting.Exact 60 min TnT and LOSOutcomes at 30 days

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1594
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fastidious adherence to 0/1-hour high-sensitivity troponin T testing reduces emergency department length of stay in patients presenting with suspected acute coronary syndromes

W. Alazrag, J. French, Hanan Idris, Ian Ferguson et al.
European Heart Journal
Acute Myocardial Infarction Research
article

Fastidious adherence to 0/1-hour high-sensitivity troponin T testing reduces emergency department length of stay in patients presenting with suspected acute coronary syndromes

W. Alazrag, J. French, Hanan Idris, Ian Ferguson, Paul M Middleton, C. Juergens, G Vimalaratnam
article en

Abstract

Abstract Background High-sensitivity cardiac troponins (hs-cTn) are key clinical biomarkers in patients presenting with suspected acute coronary syndromes (ACS) to Emergency Departments (EDs). They have facilitated rapid 0h/1h troponin testing protocols, leading to safe, effective, and efficient triage of patients. However, early distinction of myocardial infarction (MI), which has a reported frequency of less than 10% in most cohorts, from the apparently stable hs-cTn elevations of chronic myocardial injury (CMI) remains a challenge. Often CMI patients require confirmation by further testing and observation, prolonging patient length of stay. Further, reliably obtaining serial hs-cTn samples at 60-minutes in a busy ED setting may be difficult. A potential explanation for only 5-6% of Australian sites adopting 0h/1h hs-cTn testing. Methods and Results We undertook a case-control study between March and August 2023 among patients with suspected ACS presenting to Liverpool Hospital ED (Sydney, Australia). 185 patients (cases) underwent hs-cTnT sampling at 30- and 60-minutes (± 5 minutes) after baseline. Diagnosis of MI was made in 8.6%, 35.7% were placed into a further observation group and MI ruled-out in 55.7%. The latter two groups were matched to 169 patients (controls) who received ‘usual’ care, which was a 0h/1h hs-cTnT testing protocol. The case and control arms were matched by age, gender, time from symptom onset and main presenting symptom. Control patients had a median sampling interval of 118 [85 to 174] minutes, rather 60 minutes as the protocol directs. When comparing the paired differences between the case and control arms, there was a mean reduction in length of stay of 104 (95% CI: 41 to 186, P = 0.01) and 47 (95% CI: 11 to 84, P = 0.01) minutes, for the observation and rule-out MI groups respectively. The figure shows the distribution of lengths of stay by group. Among the rule-out group, Wilcoxon signed rank test indicated the control arm had a longer median length of stay of 6.3 [5.1 to 8.4] hours, compared to 5.0 [4.5 to 7.1] hours in the case arm (P=0.005). Similarly, in the further observation group, control patients also had a longer median length of stay of 9.2 [6.9 to 10.4] hours compared to case patients of 8.1 [5.1 to 10.3] hours (P = 0.009). At 30-days, ED representation rates were 10.7% in controls and 8.3% in cases, rehospitalisation 3.6% in controls and 5.3% in cases, cardiac death 0% in both arms and non-cardiac death 1% in both arms. There were no differences in event rates between each arm (P > 0.05). Conclusion Accurate 0h/1h hs-cTnT testing reduces patient length of stay in ED and offers more personalised prediction of MI risk. The importance of adherence to protocol-directed sampling times is clear, where further studies are required regarding routine implementation in a busy ED setting.Exact 60 min TnT and LOSOutcomes at 30 days

European Heart JournalVol. 45(Supplement_1)
Fiona Stanley Hospital (AU), Liverpool Hospital (AU), UNSW Sydney (AU)
Openalex Percentile: Top 67%
Acute Myocardial Infarction Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.