Assessment of coronary microvascular function with absolute coronary fl ow measurements

Abstract Background Reliable assessment of microvascular function is essential, both in research setting and clinical practice. New techniques, such as continuous coronary thermodilution, are very promising and could revolutionize the field. However, there is a need for proper validation before widespread use is possible. Purpose The goals of this study were: 1. to validate the potential of saline infusion to generate maximum hyperemia in vivo. 2. to validate absolute blood flow (ABF) measured with continuous coronary thermodilution at higher (40-50 ml/min) infusion speeds 3. To assess the safety of higher infusion speeds. Methods Fourteen closed-chest sheep underwent ABF measurements with increasing saline infusion speeds with and without adenosine. Another seven open-chest sheep underwent these measurements with epicardial doppler flow probes on both the left anterior descending artery and left circumflex coronary artery. Maximal hyperemia was defined as maximal flow after 45 seconds of proximal occlusion. The principles of laboratory animal care and all national regulations were followed. Results 20 ml/min of saline infusion induced lower hyperemic coronary flow (140 vs 191 ml/min, p=0.0165) and lower coronary flow reserve (CFR) (1.82 vs 3.21, p= <0.0001) than coronary occlusion. In contrast, 30 ml/min resulted in flow (196 vs 192 ml/min, p=0.8292) and CFR (2.77 vs 3.21, p=0.1107) that were not different from post-occlusion. There was a significant flow overestimation bias (Bland-Altman: Bias ± SD: -73.09 ± 30.52, 95% Limits of agreement: -132.9 to -13.27) with 40-50ml/min of saline. Occasionally, higher saline infusion rates resulted in ischemic ECG-changes and ventricular fibrillation (9.5% at 50 ml/min). Conclusions Continuous saline infusion of 30ml/min, but not 20 ml/min, induced maximal hyperemia. ABF measured with saline infusion speeds of 40-50 ml/min was not accurate nor safe, and should therefore be avoided.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1280
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of coronary microvascular function with absolute coronary fl ow measurements

Johan Bennett, Lennert Minten, Christophe Dubois, Keir McCutcheon et al.
European Heart Journal
Cardiac Imaging and Diagnostics
article

Assessment of coronary microvascular function with absolute coronary fl ow measurements

Johan Bennett, Lennert Minten, Christophe Dubois, Keir McCutcheon, Wouter Oosterlinck, William F. Fearon
article en

Abstract

Abstract Background Reliable assessment of microvascular function is essential, both in research setting and clinical practice. New techniques, such as continuous coronary thermodilution, are very promising and could revolutionize the field. However, there is a need for proper validation before widespread use is possible. Purpose The goals of this study were: 1. to validate the potential of saline infusion to generate maximum hyperemia in vivo. 2. to validate absolute blood flow (ABF) measured with continuous coronary thermodilution at higher (40-50 ml/min) infusion speeds 3. To assess the safety of higher infusion speeds. Methods Fourteen closed-chest sheep underwent ABF measurements with increasing saline infusion speeds with and without adenosine. Another seven open-chest sheep underwent these measurements with epicardial doppler flow probes on both the left anterior descending artery and left circumflex coronary artery. Maximal hyperemia was defined as maximal flow after 45 seconds of proximal occlusion. The principles of laboratory animal care and all national regulations were followed. Results 20 ml/min of saline infusion induced lower hyperemic coronary flow (140 vs 191 ml/min, p=0.0165) and lower coronary flow reserve (CFR) (1.82 vs 3.21, p= <0.0001) than coronary occlusion. In contrast, 30 ml/min resulted in flow (196 vs 192 ml/min, p=0.8292) and CFR (2.77 vs 3.21, p=0.1107) that were not different from post-occlusion. There was a significant flow overestimation bias (Bland-Altman: Bias ± SD: -73.09 ± 30.52, 95% Limits of agreement: -132.9 to -13.27) with 40-50ml/min of saline. Occasionally, higher saline infusion rates resulted in ischemic ECG-changes and ventricular fibrillation (9.5% at 50 ml/min). Conclusions Continuous saline infusion of 30ml/min, but not 20 ml/min, induced maximal hyperemia. ABF measured with saline infusion speeds of 40-50 ml/min was not accurate nor safe, and should therefore be avoided.

European Heart JournalVol. 45(Supplement_1)
Universitair Ziekenhuis Leuven (BE), Stanford University (US), KU Leuven (BE)
Fonds Wetenschappelijk Onderzoek, Vlaamse regering
Openalex Percentile: Top 68%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.