Changes of angiography-derived coronary microcirculatory resistance before and after drug-coated balloon treatment

Abstract Background Drug coated balloon (DCB) is a treatment option for a lesion in a small coronary artery. The effect of DCB is proven in mechanistic and clinical outcomes, however, its influence on the microvascular function has not been elucidated. In addition, because there are differences in the types of drugs and coatings among different DCBs, their effects on microvascular function may vary. Angiography-derived microcirculatory resistance (AMR) is a novel angiographic parameter calculated from angiography-derived quantitative flow ratio and flow velocity estimation. AMR is reported to have a good correlation with the wire-based index of microvascular resistance. Purpose To investigate the AMR in coronary vessels treated with sirolimus or paclitaxel coated balloon. Methods This is a subanalysis of the TRANSFORM I (The TReAtmeNt of Small Coronary Vessels: MagicTouch Sirolimus Coated Balloon) trial. TRANSFORM I is a prospective, randomized, multi-center, open-label noninferiority trial conducted in Europe that enrolled 121 patients (126 vessels) with stabilized acute coronary syndrome or chronic coronary syndrome who had at least one de novo coronary artery lesion in a small coronary vessel. Patients were randomized 1:1 to treatment with the sirolimus coated balloon (SCB) or paclitaxel coated balloon (PCB). The SCB is coated with phospholipid encapsulated sirolimus nanocarrier, whereas the PCB is coated with crystalline paclitaxel. In this subanalysis, angiography at baseline and post-procedure were analyzed to calculate the AMR by an imaging core lab. Coronary microvascular dysfunction (CMD) was defined as AMR≧2.5 mmHg*s/cm. Results In the total of 126 vessels, 63 were included in each of the SCB and PCB group. Angiography both at baseline and post-procedure were analyzable for AMR in 59 vessels in SCB and in 59 vessels in PCB group. In SCB group, the median AMR increased significantly after procedure (baseline; 2.03 [1.58-2.42], post-procedure;2.21 [1.78-2.53], p=0.03). However, the proportion of vessels with CMD did not significantly change (baseline; 22.0% [13/59], post-procedure; 32.2% [18/59], p=0.19) (Figure). In the PCB group, the median AMR increased significantly after procedure (baseline; 2.22 [1.66-2.53], post-procedure;2.45 [1.93-2.96], p=0.003). Furthermore, the proportion of vessels with CMD significantly increased (baseline; 27.1% [16/59], post-procedure; 47.5% [28/59], p=0.046) (Figure). The AMR measurement was not significantly different between SCB and PCB at baseline (p=0.53), but it was significantly higher in PCB than in SCB at post-procedure (p=0.04). Conclusion After DCB treatment, AMR significantly increased in both arms. The proportion of the vessel with CMD after procedure did not significantly change in the SCB group but increased in the PCB group. The potential mechanism of increase in AMR after DCB treatment (e.g. embolization of small crystals) may warrant further investigation.Proportion of AMR≥2.5

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1285
Citations
1
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Changes of angiography-derived coronary microcirculatory resistance before and after drug-coated balloon treatment

Kotaro Miyashita, Roberto Nerla, Yoshinobu Onuma, Antonio Colombo et al.
1 citations
European Heart Journal
Coronary Interventions and Diagnostics
0.57
article

Changes of angiography-derived coronary microcirculatory resistance before and after drug-coated balloon treatment

Kotaro Miyashita, Roberto Nerla, Yoshinobu Onuma, Antonio Colombo, Bernhard Reimers, Emelyne Sevestre, Faisal Sharif, Carlo Di Mario, Akihiro Tobe, Sandeep Basavarajaiah, Luca Testa, Bernardo Cortese, Patrick W. Serruys, Marie-Angèle Morel
article en
1 citations

Abstract

Abstract Background Drug coated balloon (DCB) is a treatment option for a lesion in a small coronary artery. The effect of DCB is proven in mechanistic and clinical outcomes, however, its influence on the microvascular function has not been elucidated. In addition, because there are differences in the types of drugs and coatings among different DCBs, their effects on microvascular function may vary. Angiography-derived microcirculatory resistance (AMR) is a novel angiographic parameter calculated from angiography-derived quantitative flow ratio and flow velocity estimation. AMR is reported to have a good correlation with the wire-based index of microvascular resistance. Purpose To investigate the AMR in coronary vessels treated with sirolimus or paclitaxel coated balloon. Methods This is a subanalysis of the TRANSFORM I (The TReAtmeNt of Small Coronary Vessels: MagicTouch Sirolimus Coated Balloon) trial. TRANSFORM I is a prospective, randomized, multi-center, open-label noninferiority trial conducted in Europe that enrolled 121 patients (126 vessels) with stabilized acute coronary syndrome or chronic coronary syndrome who had at least one de novo coronary artery lesion in a small coronary vessel. Patients were randomized 1:1 to treatment with the sirolimus coated balloon (SCB) or paclitaxel coated balloon (PCB). The SCB is coated with phospholipid encapsulated sirolimus nanocarrier, whereas the PCB is coated with crystalline paclitaxel. In this subanalysis, angiography at baseline and post-procedure were analyzed to calculate the AMR by an imaging core lab. Coronary microvascular dysfunction (CMD) was defined as AMR≧2.5 mmHg*s/cm. Results In the total of 126 vessels, 63 were included in each of the SCB and PCB group. Angiography both at baseline and post-procedure were analyzable for AMR in 59 vessels in SCB and in 59 vessels in PCB group. In SCB group, the median AMR increased significantly after procedure (baseline; 2.03 [1.58-2.42], post-procedure;2.21 [1.78-2.53], p=0.03). However, the proportion of vessels with CMD did not significantly change (baseline; 22.0% [13/59], post-procedure; 32.2% [18/59], p=0.19) (Figure). In the PCB group, the median AMR increased significantly after procedure (baseline; 2.22 [1.66-2.53], post-procedure;2.45 [1.93-2.96], p=0.003). Furthermore, the proportion of vessels with CMD significantly increased (baseline; 27.1% [16/59], post-procedure; 47.5% [28/59], p=0.046) (Figure). The AMR measurement was not significantly different between SCB and PCB at baseline (p=0.53), but it was significantly higher in PCB than in SCB at post-procedure (p=0.04). Conclusion After DCB treatment, AMR significantly increased in both arms. The proportion of the vessel with CMD after procedure did not significantly change in the SCB group but increased in the PCB group. The potential mechanism of increase in AMR after DCB treatment (e.g. embolization of small crystals) may warrant further investigation.Proportion of AMR≥2.5

European Heart JournalVol. 45(Supplement_1)
Humanitas University (IT), IRCCS Policlinico San Donato (IT), Maria Cecilia Hospital (IT), Heartlands Hospital (GB), Azienda Ospedaliero-Universitaria Careggi (IT), Cardiovascular Research Center (BR)
Openalex Percentile: Top 28%
Coronary Interventions and Diagnostics
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.