Thermoluminescence and Kinetic Parameters of Beta Rays Irradiated Egyptian Muscovite

The current work was going to study the dosimetric properties of Egyptian muscovite minerals irradiated with β-rays using the thermoluminescence technique (TL). The analysis of the TL glow curves was done using the (T<sub>m</sub> - T<sub>stop</sub>) and the initial rise methods. The deconvolution of the muscovite glow curves was analyzed to have eight superimposed trapping peaks. These trapes were located at 0.72, 0.80, 0.98, 1.09, 1.19, 1.30, 1.50, and 1.59 eV. Muscovite samples were studied at doses up to 330 Gy and exhibited good linearity in relation to beta radiation. The kinetic parameters, sensitivity, and dosimetric characteristics were evaluated. High accuracy was achieved through the repeatability of TL measurements.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2024-10-01
DOI
https://doi.org/10.1002/bio.70002
Citations
1
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermoluminescence and Kinetic Parameters of Beta Rays Irradiated Egyptian Muscovite

Nabil El‐Faramawy, Shrouk Farouk
1 citations
Luminescence
Luminescence Properties of Advanced Materials
0.12
article

Thermoluminescence and Kinetic Parameters of Beta Rays Irradiated Egyptian Muscovite

Nabil El‐Faramawy, Shrouk Farouk
article en
1 citations

Abstract

The current work was going to study the dosimetric properties of Egyptian muscovite minerals irradiated with β-rays using the thermoluminescence technique (TL). The analysis of the TL glow curves was done using the (T<sub>m</sub> - T<sub>stop</sub>) and the initial rise methods. The deconvolution of the muscovite glow curves was analyzed to have eight superimposed trapping peaks. These trapes were located at 0.72, 0.80, 0.98, 1.09, 1.19, 1.30, 1.50, and 1.59 eV. Muscovite samples were studied at doses up to 330 Gy and exhibited good linearity in relation to beta radiation. The kinetic parameters, sensitivity, and dosimetric characteristics were evaluated. High accuracy was achieved through the repeatability of TL measurements.

LuminescenceVol. 39(10)
Ain Shams University (EG)
Openalex Percentile: Top 59%
Luminescence Properties of Advanced Materials
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.