Feasibility, accuracy, and reproducibility of device sizing in virtual reality for percutaneous left atrial appendage closure - a single center study

Abstract Background Left atrial appendage closure (LAAC) is a safe and effective procedure for stroke prevention in patient with non-valvular atrial fibrillation. Procedural planning and device sizing remains challenging due to the highly complex and variable three-dimensional (3D) anatomy of the left atrial appendage (LAA). Virtual reality (VR) is a innovative, recent technology allowing a superior spatial orientation visualization of 3D imaging datasets. Purpose Therefore, we aimed to evaluate feasibility and accuracy of LAA measurements in VR for device sizing in patients planned for LAAC. Methods Twenty-one patients (79±7 years, 62% male) with non-valvular atrial fibrillation scheduled for LAAC were randomly included in our study. Preprocedural a multi-slice computed tomography (MSCT) was performed for device sizing in all patients. MSCT-based 3D models were established and visualized in VR using a dedicated software (VMersive, Warsaw, Poland). LAA dimensions (Ostium, landing zone (LZ), and depth) were assessed directly in the virtual environment. Conventional measurements of LAA ostium, landing zone (LZ) and depth using commercially available software were compared to measurements in VR. Results 3D reconstruction of MSCT datasets and visualization in VR were successfully performed automatically in all patients within a few seconds. MSCT and VR demonstrated good correlations for ostium minimum (r = 0.93), maximum (r = 0.8) and mean (r = 0.88, all p<0.001) diameters. Additionally, LZ minimum (r=0.84), maximum (r=0.86) and mean (r=0.9) diameters showed good correlation (all p<0.001). Moderate correlation was observed for depth measurements (r=0.76, p<0.001). Furthermore, intraclass correlation coefficients ranging from 0.88 to 0.98 denoted high inter- and intraobserver agreement. Conclusion Immersive VR allows highly feasible, accurate and reproducible measurements of the LAA dimensions directly in the virtual environment, hence enabling accurate device sizing for LAAC.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.086
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility, accuracy, and reproducibility of device sizing in virtual reality for percutaneous left atrial appendage closure - a single center study

Tobias Zeus, Dominika Kanschik, Shazia Afzal, Oliver Maier et al.
European Heart Journal
Atrial Fibrillation Management and Outcomes
article

Feasibility, accuracy, and reproducibility of device sizing in virtual reality for percutaneous left atrial appendage closure - a single center study

Tobias Zeus, Dominika Kanschik, Shazia Afzal, Oliver Maier, Nikos Werner, Georg Wolff, Hadi Heidari, M K Kelm, C Jung
article en

Abstract

Abstract Background Left atrial appendage closure (LAAC) is a safe and effective procedure for stroke prevention in patient with non-valvular atrial fibrillation. Procedural planning and device sizing remains challenging due to the highly complex and variable three-dimensional (3D) anatomy of the left atrial appendage (LAA). Virtual reality (VR) is a innovative, recent technology allowing a superior spatial orientation visualization of 3D imaging datasets. Purpose Therefore, we aimed to evaluate feasibility and accuracy of LAA measurements in VR for device sizing in patients planned for LAAC. Methods Twenty-one patients (79±7 years, 62% male) with non-valvular atrial fibrillation scheduled for LAAC were randomly included in our study. Preprocedural a multi-slice computed tomography (MSCT) was performed for device sizing in all patients. MSCT-based 3D models were established and visualized in VR using a dedicated software (VMersive, Warsaw, Poland). LAA dimensions (Ostium, landing zone (LZ), and depth) were assessed directly in the virtual environment. Conventional measurements of LAA ostium, landing zone (LZ) and depth using commercially available software were compared to measurements in VR. Results 3D reconstruction of MSCT datasets and visualization in VR were successfully performed automatically in all patients within a few seconds. MSCT and VR demonstrated good correlations for ostium minimum (r = 0.93), maximum (r = 0.8) and mean (r = 0.88, all p<0.001) diameters. Additionally, LZ minimum (r=0.84), maximum (r=0.86) and mean (r=0.9) diameters showed good correlation (all p<0.001). Moderate correlation was observed for depth measurements (r=0.76, p<0.001). Furthermore, intraclass correlation coefficients ranging from 0.88 to 0.98 denoted high inter- and intraobserver agreement. Conclusion Immersive VR allows highly feasible, accurate and reproducible measurements of the LAA dimensions directly in the virtual environment, hence enabling accurate device sizing for LAAC.

European Heart JournalVol. 45(Supplement_1)
Krankenhaus der Barmherzigen Brüder Trier (DE), Düsseldorf University Hospital (DE)
Openalex Percentile: Top 67%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.