Incidental non-infectious masses on cardiac implantable electronic device leads

Abstract Introduction Incidentally detected masses on the leads of cardiac implantable electronic devices (CIED) present a clinical challenge, raising suspicion of infective device endocarditis. Data on the prevalence of such findings are scarce and outdated. Purpose Our aim was to determine the prevalence and evaluate predisposing clinical factors of incidental non-infectious CIED lead masses during transoesophageal echocardiography (TOE). Methods In this retrospective single-centre study, we analysed all TOE examinations performed in patients with CIED leads between January 2010 and November 2023. Patients with suspected or confirmed infectious endocarditis were excluded from this study. Patients with and without incidental non-infectious lead masses were compared regarding clinical characteristics, anticoagulation, type of CIED, and indication for TOE. Results In total, 120 patients with CIED were included. Twenty-five patients (20,8%) presented with non-infectious CIED lead masses. Laboratory findings and cardiovascular risk factors, such as arterial hypertension, dyslipidaemia, diabetes mellitus or chronic kidney disease did not differ significantly between both groups. Moreover, no association was observed between the incidence of CIED lead masses and the type of CIED implanted. Of notice, patients without therapeutic anticoagulation had significantly higher prevalence of CIED lead masses (OR 2.59, 95% CI: 1.04-6.46.; p=0.02), whereas the distribution of CHA2DS2-VASc scores did not differ significantly between both groups. Conclusion Non-infectious CIED lead masses in TOE is a frequent incidental finding. The absence of the oral anticoagulation seems to be the only clinical risk factor for such finding in our study, suggesting possible thrombogenic etiology. The high prevalence of incidental non-infectious lead masses should be kept in mind in order to avoid overdiagnosis of CIED infection and unnecessary lead extraction.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.008
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incidental non-infectious masses on cardiac implantable electronic device leads

Samuel Fernandes, R Silva, Sofía Rocha, Filipe Silva Vilela et al.
European Heart Journal
Cardiac pacing and defibrillation studies
article

Incidental non-infectious masses on cardiac implantable electronic device leads

Samuel Fernandes, R Silva, Sofía Rocha, Filipe Silva Vilela, Carla Ferreira, Carolina L. Zilli Vieira, F. Mané, J Marques, MA Dias, Inês Conde
article en

Abstract

Abstract Introduction Incidentally detected masses on the leads of cardiac implantable electronic devices (CIED) present a clinical challenge, raising suspicion of infective device endocarditis. Data on the prevalence of such findings are scarce and outdated. Purpose Our aim was to determine the prevalence and evaluate predisposing clinical factors of incidental non-infectious CIED lead masses during transoesophageal echocardiography (TOE). Methods In this retrospective single-centre study, we analysed all TOE examinations performed in patients with CIED leads between January 2010 and November 2023. Patients with suspected or confirmed infectious endocarditis were excluded from this study. Patients with and without incidental non-infectious lead masses were compared regarding clinical characteristics, anticoagulation, type of CIED, and indication for TOE. Results In total, 120 patients with CIED were included. Twenty-five patients (20,8%) presented with non-infectious CIED lead masses. Laboratory findings and cardiovascular risk factors, such as arterial hypertension, dyslipidaemia, diabetes mellitus or chronic kidney disease did not differ significantly between both groups. Moreover, no association was observed between the incidence of CIED lead masses and the type of CIED implanted. Of notice, patients without therapeutic anticoagulation had significantly higher prevalence of CIED lead masses (OR 2.59, 95% CI: 1.04-6.46.; p=0.02), whereas the distribution of CHA2DS2-VASc scores did not differ significantly between both groups. Conclusion Non-infectious CIED lead masses in TOE is a frequent incidental finding. The absence of the oral anticoagulation seems to be the only clinical risk factor for such finding in our study, suggesting possible thrombogenic etiology. The high prevalence of incidental non-infectious lead masses should be kept in mind in order to avoid overdiagnosis of CIED infection and unnecessary lead extraction.

European Heart JournalVol. 45(Supplement_1)
Hospital Braga (PT)
Openalex Percentile: Top 67%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.