Ventricular arrhythmia characteristics after left ventricular assist device implantation

Abstract Background Ventricular arrhythmia (VA) characteristics in patients with advanced heart failure (HF) and left ventricular assist devices (LVADs) are currently poorly studied. Methods Patients with advanced HF implanted with third-generation LVADs during 2019-2023 were enrolled, and six-month post-LVAD VA events were retrospectively analyzed. Baseline characteristics, 6-month VA events, Holter monitoring and ambulatory blood pressure were also analyzed. Post-LVAD VA events were categorized as new right bundle-branch block (RBBB) superiorly directed VA and prior VA recurrence. Results Fifty-four advanced HF patients (90.7% male, 50.0±13.7 years old) who underwent LVAD (CH-VAD: n=23; Evaheart2: n=10; Corheart6: n=21) were consecutively enrolled in this study. Twenty-two patients suffered post-LVAD VA events (15 new RBBB superiorly directed VA, 7 prior VA recurrence), and 94.4% of the patients were hemodynamically stable. A total of 46.3% of the patients presented with a 50% reduction in VA burden, and amiodarone use decreased from 25.9% to 16.7%. The nighttime mean arterial pressure (MAP) and maximum inferior venous cava (IVC) diameter had opposite predictive effects on the new RBBB VA, and the post-LVAD left ventricular ejection fraction (LVEF) was negatively correlated with the prior VA recurrence. Multivariate analysis revealed that a higher nighttime MAP/IVC ratio (OR 2.24, 95% CI 2.22-4.52; P=0.025) and a lower post-LVAD LVEF (OR 0.75, 95% CI 0.57-0.99; P=0.048) were independently related to the new RBBB superiorly directed VA and prior VA recurrence, respectively. Conclusion The overall VA burden decreased after LVAD implantation. Volume deficiency and poor post-LVAD cardiac function were associated with different VA patterns.Changes in VAs pre- and 6 monthsVA distributions of patients

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1113
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventricular arrhythmia characteristics after left ventricular assist device implantation

X Q Wang, Lu Zou, Fei Duan, Houcong Chen et al.
European Heart Journal
Mechanical Circulatory Support Devices
article

Ventricular arrhythmia characteristics after left ventricular assist device implantation

X Q Wang, Lu Zou, Fei Duan, Houcong Chen, Xiaoliang Zhou, Xiang Li, Lihua Yu, Juan Du, Ping Qing, S S Hu, Y Yao
article en

Abstract

Abstract Background Ventricular arrhythmia (VA) characteristics in patients with advanced heart failure (HF) and left ventricular assist devices (LVADs) are currently poorly studied. Methods Patients with advanced HF implanted with third-generation LVADs during 2019-2023 were enrolled, and six-month post-LVAD VA events were retrospectively analyzed. Baseline characteristics, 6-month VA events, Holter monitoring and ambulatory blood pressure were also analyzed. Post-LVAD VA events were categorized as new right bundle-branch block (RBBB) superiorly directed VA and prior VA recurrence. Results Fifty-four advanced HF patients (90.7% male, 50.0±13.7 years old) who underwent LVAD (CH-VAD: n=23; Evaheart2: n=10; Corheart6: n=21) were consecutively enrolled in this study. Twenty-two patients suffered post-LVAD VA events (15 new RBBB superiorly directed VA, 7 prior VA recurrence), and 94.4% of the patients were hemodynamically stable. A total of 46.3% of the patients presented with a 50% reduction in VA burden, and amiodarone use decreased from 25.9% to 16.7%. The nighttime mean arterial pressure (MAP) and maximum inferior venous cava (IVC) diameter had opposite predictive effects on the new RBBB VA, and the post-LVAD left ventricular ejection fraction (LVEF) was negatively correlated with the prior VA recurrence. Multivariate analysis revealed that a higher nighttime MAP/IVC ratio (OR 2.24, 95% CI 2.22-4.52; P=0.025) and a lower post-LVAD LVEF (OR 0.75, 95% CI 0.57-0.99; P=0.048) were independently related to the new RBBB superiorly directed VA and prior VA recurrence, respectively. Conclusion The overall VA burden decreased after LVAD implantation. Volume deficiency and poor post-LVAD cardiac function were associated with different VA patterns.Changes in VAs pre- and 6 monthsVA distributions of patients

European Heart JournalVol. 45(Supplement_1)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Fu Wai Hospital (CN)
No poverty
Openalex Percentile: Top 83%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.