Right ventricular to pulmonary artery coupling credicts poor outcomes after interatrial shunting in heart failure

Abstract Background Left atrial decompression is under investigation for heart failure (HF) with the potential to improve symptoms and potentially clinical outcomes. However, heterogeneous outcomes have been observed in randomized controlled studies. Purpose This study aimed to explore whether right ventricular (RV) -pulmonary artery (PA) coupling, as assessed from the tricuspid annular plane systolic excursion (TAPSE) /systolic PA pressure ratio, can be useful in predicting outcomes after implantation of the interatrial shunting device. Methods A total of 106 HF patients, n=62 with reduced ejection fraction (HFrEF), n=44 with preserved ejection fraction (HFpEF), were prospectively enrolled in the PRELIEVE registry with the Atrial Flow Regulator (AFR) implantation. Serious adverse events included cardiovascular mortality and HF worsening (W). Results Serious adverse events (SAEs) occurred in a total of 19 (18%) patients. There were no differences in baseline comorbidities, KCCQ scores, the 6-minute walking distance between patients with and without SAEs (Table). Patients with SAEs showed higher systolic pulmonary arterial pressure, NT-proBNP, serum creatinine and lower TAPSE/PASP ratio. Incidence of SAEs was higher in patients within the first TAPSE/PASP vs the third tertile (59% vs 12%, p=0.026), respectively. A TAPSE/PASP of <0.55 was identified to bear the most optimal sensitivity to predict the event (AUC=0.683, CI95% (0.533-0.833). Conclusion The reduced TAPSE/PASP ratio was associated with higher rates of serious adverse events in patients with heart failure undergoing controlled inter-atrial shunting. The hypothesis generating finding that reduced RV-PA coupling may identify potential clinical non-responders to left atrial decompression should be further prospectively validated.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1028
Citations
1
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Right ventricular to pulmonary artery coupling credicts poor outcomes after interatrial shunting in heart failure

Raymond Pfister, Barış Kılıçaslan, Felix Mahfoud, R Ozdemir et al.
1 citations
European Heart Journal
Congenital Heart Disease Studies
0.39
article

Right ventricular to pulmonary artery coupling credicts poor outcomes after interatrial shunting in heart failure

Raymond Pfister, Barış Kılıçaslan, Felix Mahfoud, R Ozdemir, Jozef Bartúnek, C Paitazoglou, Nijad Bakhshaliyev, Martin Bergmann, S. D. Anker
article en
1 citations

Abstract

Abstract Background Left atrial decompression is under investigation for heart failure (HF) with the potential to improve symptoms and potentially clinical outcomes. However, heterogeneous outcomes have been observed in randomized controlled studies. Purpose This study aimed to explore whether right ventricular (RV) -pulmonary artery (PA) coupling, as assessed from the tricuspid annular plane systolic excursion (TAPSE) /systolic PA pressure ratio, can be useful in predicting outcomes after implantation of the interatrial shunting device. Methods A total of 106 HF patients, n=62 with reduced ejection fraction (HFrEF), n=44 with preserved ejection fraction (HFpEF), were prospectively enrolled in the PRELIEVE registry with the Atrial Flow Regulator (AFR) implantation. Serious adverse events included cardiovascular mortality and HF worsening (W). Results Serious adverse events (SAEs) occurred in a total of 19 (18%) patients. There were no differences in baseline comorbidities, KCCQ scores, the 6-minute walking distance between patients with and without SAEs (Table). Patients with SAEs showed higher systolic pulmonary arterial pressure, NT-proBNP, serum creatinine and lower TAPSE/PASP ratio. Incidence of SAEs was higher in patients within the first TAPSE/PASP vs the third tertile (59% vs 12%, p=0.026), respectively. A TAPSE/PASP of <0.55 was identified to bear the most optimal sensitivity to predict the event (AUC=0.683, CI95% (0.533-0.833). Conclusion The reduced TAPSE/PASP ratio was associated with higher rates of serious adverse events in patients with heart failure undergoing controlled inter-atrial shunting. The hypothesis generating finding that reduced RV-PA coupling may identify potential clinical non-responders to left atrial decompression should be further prospectively validated.

European Heart JournalVol. 45(Supplement_1)
Bezmiâlem Vakıf Üniversitesi (TR), Cardiovascular Research Center (BR), Izmir Tepecik Eğitim ve Araştırma Hastanesi (TR), University Hospital Cologne (DE), Kocaeli Üniversitesi (TR), Charité - Universitätsmedizin Berlin (DE), Saarland University (DE)
Openalex Percentile: Top 33%
Congenital Heart Disease Studies
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.