Automated selection of echocardiographic views using a novel artificial intelligence software

Abstract Background/Introduction Evaluation of a single echocardiographic study involves sorting, selecting, measuring and interpreting a large number of images. As these steps are currently performed manually, this can turn into a repetitive, time-consuming and tedious task. Although the use of artificial intelligence (AI) software could potentially improve this entire workflow, most of the efforts have been focused on measurement automatization. Incorporation of automated selection of echocardiographic views could further optimize this process. Purpose We investigated whether an AI-derived measurements software can be supplemented by automated view selection using an AI model. We hypothesized that automated selection of echocardiographic views yields similar results compared to manually selected views when using the same tool for automated measurements in both groups (Figure 1, top). Methods We trained an AI model (convolutional neural network) to recognize the main standard 2D echocardiographic views. This model was trained on individual frames from 20,000 DICOM clips to predict a specific cardiac view, based on the view annotation provided by an echocardiography expert (ground-truth). We then selected a test set of 5,000 DICOMs where we applied the AI model to all images in the study. We selected the highest-ranking apical 2 chamber (A2C) and apical 4 chamber (A4C) images, based on the model’s output probability (Figure 1, bottom). For the same 21 studies, an expert selected the best A2C and A4C image for left ventricular volumes and ejection fraction measurements. Then, we ran Philips AutoMeasure both on manually and automatically selected images. We then compared the measurement values for statistical significance using a pair-wise t-test, see Figure 2. Results The AI model achieved an accuracy of 96% and AUC of 0.99 on the test set. The results obtained when comparing the automatic and manually selected images in the 21 studies are shown in Figure 2. For all the measured parameters, there was no statistically significant difference in mean values between both selection methods. Conclusions Manual and AI-derived selection of standard echocardiographic images do not lead to a statistically significant difference in automated measurements, suggesting that incorporation of automated view selection may contribute to improve daily echocardiographic workflow. Future research could aim in extending these findings to more cardiac views, parameters, and populations.Comparison of the approachesResults

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.097
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated selection of echocardiographic views using a novel artificial intelligence software

Juan Ignacio Cotella, S Wehle, Victor Mor‐Avi, Akshay Chaudhari et al.
European Heart Journal
Radiomics and Machine Learning in Medical Imaging
article

Automated selection of echocardiographic views using a novel artificial intelligence software

Juan Ignacio Cotella, S Wehle, Victor Mor‐Avi, Akshay Chaudhari, Nils Gessert, Irina Waechter‐Stehle, Jeremy Slivnick, Diana Szasz, RM Lang
article en

Abstract

Abstract Background/Introduction Evaluation of a single echocardiographic study involves sorting, selecting, measuring and interpreting a large number of images. As these steps are currently performed manually, this can turn into a repetitive, time-consuming and tedious task. Although the use of artificial intelligence (AI) software could potentially improve this entire workflow, most of the efforts have been focused on measurement automatization. Incorporation of automated selection of echocardiographic views could further optimize this process. Purpose We investigated whether an AI-derived measurements software can be supplemented by automated view selection using an AI model. We hypothesized that automated selection of echocardiographic views yields similar results compared to manually selected views when using the same tool for automated measurements in both groups (Figure 1, top). Methods We trained an AI model (convolutional neural network) to recognize the main standard 2D echocardiographic views. This model was trained on individual frames from 20,000 DICOM clips to predict a specific cardiac view, based on the view annotation provided by an echocardiography expert (ground-truth). We then selected a test set of 5,000 DICOMs where we applied the AI model to all images in the study. We selected the highest-ranking apical 2 chamber (A2C) and apical 4 chamber (A4C) images, based on the model’s output probability (Figure 1, bottom). For the same 21 studies, an expert selected the best A2C and A4C image for left ventricular volumes and ejection fraction measurements. Then, we ran Philips AutoMeasure both on manually and automatically selected images. We then compared the measurement values for statistical significance using a pair-wise t-test, see Figure 2. Results The AI model achieved an accuracy of 96% and AUC of 0.99 on the test set. The results obtained when comparing the automatic and manually selected images in the 21 studies are shown in Figure 2. For all the measured parameters, there was no statistically significant difference in mean values between both selection methods. Conclusions Manual and AI-derived selection of standard echocardiographic images do not lead to a statistically significant difference in automated measurements, suggesting that incorporation of automated view selection may contribute to improve daily echocardiographic workflow. Future research could aim in extending these findings to more cardiac views, parameters, and populations.Comparison of the approachesResults

European Heart JournalVol. 45(Supplement_1)
Philips (Finland) (FI), University of Chicago Medical Center (US), Philips (Germany) (DE)
Openalex Percentile: Top 68%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.