Ventricular tachycardia burden in heart failure with reduced ejection fraction - can we rely on optimized medical therapy

Abstract Introduction Implantation of cardioverter-defibrillator and/or resynchronization (ICD and CRT-D) devices is aimed to prevent sudden cardiac death, fatal complication of heart failure with reduced ejection fraction (HFrEF). Guidelines propose a period of 3 months receiving maximally titrated guideline-directed medical therapy (GDMT) prior to implantation. Ventricular tachycardia (VT) burden in HFrEF has been related to worse outcomes. The effect of GDMT up-titration on VT incidence after device implantation has not yet been fully clarified. Purpose The main goal of this study is to examine the effects of GDMT evidence-based target doses on VT and appropriate device therapy (ADT) incidence in patients with HFrEF implanted with ICD or CRT-D. Methods This registry-based study included patients with HFrEF who were implanted with ICD or CRT-D from January 2021 to November 2023, with at least one follow-up. Titration of GDMT and incidence of VT/ADT were evaluated. We compared VT/ADT incidence in target dose group to incomplete titration group of each drug class. We also compared GDMT titration and VT/ADT incidence in CRT-D to ICD group. The Fisher exact test was used to evaluate the differences between groups. Results Data on 132 patients were collected (mean age 63±26 years, 16% female). Median follow-up time from device implantation was 201 (30-748) days. Target doses were reached for 24.4% beta blockers (BB), 37.8% angiotensin receptor neprilysin inhibitors (ARNI), 73.5% mineralocorticoid receptor antagonists (MRA), 89.5% sodium-glucose contransporter-2 inhibitors (SGLT2I), and 18.8% of complete GDMT. Total VT and ADT incidence was 32.6% and 12.9%, respectively. In target doses vs. incomplete doses groups, VT incidence was 34.4% vs. 32.0% (p=.83) for BB, 28.0% vs. 35.4% (p=.45) for ARNI, 32.0% vs. 34.3% (p=.84) for MRA, 30.1% vs. 50.0% (p=.23) for SGLT2I and 33.3% vs. 32.4% (p=1) for complete GDMT. ADT incidence was 18.8% vs. 11.0% (p=.36) for BB, 12.0% vs. 13.4% (p=1) for ARNI, 12.4% vs. 14.3% (p=.77) for MRA, 11.0% vs. 21.4% (p=.39) for SGLT2i, and 16.7% vs. 12.0% (p=.51) for complete GDMT. In CRT-D vs. ICD group, 31.5% vs. 19,2% (p=.15) BB, 44.4% vs. 33.3% (p=.21) ARNI, 79.6% vs. 69.2% (p=.16) MRA, 98.1% vs. 83.3% (p<0.05) SGLT2I; and 20.4% vs. 16.7% (p=.65) of complete GDMT were maximally titrated. VT incidence was significantly lower in CRT-D group (18.5% vs. 42.3%, p<0.05). ADT was also lower, but without statistical significance (9.3% vs. 15.4%, p=.43). Conclusions Up-titration of any individual drug or complete GDMT to the evidence-based target dose did not directly correlate with a decrease in VT or ADT incidence. Cardiac resynchronization therapy provides more room for target GDMT doses, particularly of BB. We notice only a modest trend in up-titration of GDMT in patients with CRT-D, who had significantly lower incidence of VT.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1083
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventricular tachycardia burden in heart failure with reduced ejection fraction - can we rely on optimized medical therapy

Nikola Pavlović, Petra Vitlov, Aleksandar Blivajs, Alan Šerman et al.
European Heart Journal
Cardiac Arrhythmias and Treatments
article

Ventricular tachycardia burden in heart failure with reduced ejection fraction - can we rely on optimized medical therapy

Nikola Pavlović, Petra Vitlov, Aleksandar Blivajs, Alan Šerman, Ivan Zeljković, Ana Jordán, Ivana Jurin, Šime Manola, Fran Rode, A Novák, Marta Puškadija
article en

Abstract

Abstract Introduction Implantation of cardioverter-defibrillator and/or resynchronization (ICD and CRT-D) devices is aimed to prevent sudden cardiac death, fatal complication of heart failure with reduced ejection fraction (HFrEF). Guidelines propose a period of 3 months receiving maximally titrated guideline-directed medical therapy (GDMT) prior to implantation. Ventricular tachycardia (VT) burden in HFrEF has been related to worse outcomes. The effect of GDMT up-titration on VT incidence after device implantation has not yet been fully clarified. Purpose The main goal of this study is to examine the effects of GDMT evidence-based target doses on VT and appropriate device therapy (ADT) incidence in patients with HFrEF implanted with ICD or CRT-D. Methods This registry-based study included patients with HFrEF who were implanted with ICD or CRT-D from January 2021 to November 2023, with at least one follow-up. Titration of GDMT and incidence of VT/ADT were evaluated. We compared VT/ADT incidence in target dose group to incomplete titration group of each drug class. We also compared GDMT titration and VT/ADT incidence in CRT-D to ICD group. The Fisher exact test was used to evaluate the differences between groups. Results Data on 132 patients were collected (mean age 63±26 years, 16% female). Median follow-up time from device implantation was 201 (30-748) days. Target doses were reached for 24.4% beta blockers (BB), 37.8% angiotensin receptor neprilysin inhibitors (ARNI), 73.5% mineralocorticoid receptor antagonists (MRA), 89.5% sodium-glucose contransporter-2 inhibitors (SGLT2I), and 18.8% of complete GDMT. Total VT and ADT incidence was 32.6% and 12.9%, respectively. In target doses vs. incomplete doses groups, VT incidence was 34.4% vs. 32.0% (p=.83) for BB, 28.0% vs. 35.4% (p=.45) for ARNI, 32.0% vs. 34.3% (p=.84) for MRA, 30.1% vs. 50.0% (p=.23) for SGLT2I and 33.3% vs. 32.4% (p=1) for complete GDMT. ADT incidence was 18.8% vs. 11.0% (p=.36) for BB, 12.0% vs. 13.4% (p=1) for ARNI, 12.4% vs. 14.3% (p=.77) for MRA, 11.0% vs. 21.4% (p=.39) for SGLT2i, and 16.7% vs. 12.0% (p=.51) for complete GDMT. In CRT-D vs. ICD group, 31.5% vs. 19,2% (p=.15) BB, 44.4% vs. 33.3% (p=.21) ARNI, 79.6% vs. 69.2% (p=.16) MRA, 98.1% vs. 83.3% (p<0.05) SGLT2I; and 20.4% vs. 16.7% (p=.65) of complete GDMT were maximally titrated. VT incidence was significantly lower in CRT-D group (18.5% vs. 42.3%, p<0.05). ADT was also lower, but without statistical significance (9.3% vs. 15.4%, p=.43). Conclusions Up-titration of any individual drug or complete GDMT to the evidence-based target dose did not directly correlate with a decrease in VT or ADT incidence. Cardiac resynchronization therapy provides more room for target GDMT doses, particularly of BB. We notice only a modest trend in up-titration of GDMT in patients with CRT-D, who had significantly lower incidence of VT.

European Heart JournalVol. 45(Supplement_1)
University of Zagreb (HR), University Hospital Dubrava (HR)
Openalex Percentile: Top 67%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.