Significance of mitral annulus apparatus morphometry in patients with persistent atrial fibrillation

Abstract Background Few data about mitral valve apparatus components deformation in patients with persistent atrial fibrillation are available. Four-dimensional transesophageal echocardiography (4DTEE) is an ideal imaging technique to evaluate the complex morphology of the mitral valve apparatus. Purpose The study aimed to find some characteristics in patients presenting with persistent atrial fibrillation and if some of them could be indicative of relapse after cardioversion. Methods The study enrolled 133 patients with persistent atrial fibrillation and mild/moderate functional mitral regurgitation (FMR) before cardioversion. 101 of the patients were at the first persistent atrial fibrillation episode, and 32 with relapse. After performing two-dimensional transthoracic echocardiography (2DTTE), the study included only patients with mild/moderate FMR. 4D TEE permitted a detailed examination of the mitral annulus and valve leaflets, using an E95 machine for acquisition and an ECHOPAC 204 for image postprocessing with mitral valve quantification (MVQ) software. The studied measured: annulus area (AA)3D, annulus perimeter (AP), antero-posterior diameter (APD), posteromedial-anterolateral diameter (PM-ALD), commissural diameter (CD), inter-trigonal distance (ITd), non-planar angle (NPa), mitral-aortic angle (MAa), and for the leaflets, morphological measured parameters were: anterior leaflet area (ALA), posterior leaflet area (PLA), anterior leaflet length (ALL), posterior leaflet length (PLL), anterior leaflet angle (ALa), posterior leaflet angle (PLa), tenting height (TH), tenting area (TA), tenting volume), closure line length (CLL). Results 1. We found significant statistic differences between mitral annulus apparatus components in patients with (32) and without relapse (101) after initial cardioversion: AA 3D: 3.12 vs. 11.65 (p=0.003), AP: 13.23 vs. 12.1 (p=0.0001), APD: 3.76 vs. 3.45 (p=0.0003), PM-ALD: 4.21vs 3.93 (p=0.004), CD:4.17 vs. 3.89 (p=0.002), ITd: 2.82 vs 2.74 (p=0.2), NPa: 158.5 vs 155.2 (p=0.09), MAa: 122 vs 120,7 (p=0.5), ALA: 5.73 vs. 5.18 (p=0.006), PLA: 7.04 vs. 6.09 (p < 0.0001), ALL: 2.19 vs. 2.07 (p=0.036), PLL: 1,73 vs. 1,6 (p=0.03), ALa: 15.31 vs. 18.82 (p=0.002), PLa: 21.38 vs. 25.31 (p=0.01), TH: 0.83 vs. 0.63 (p=0.001), TA: 1.63 vs. 1.32 (p=0.007), TV: 2.75 vs. 2.13 (p=0.007). 2. We found correlations between mitral valve leaflets area and coaptation length in atrial fibrillation patients with (ALA: r=0.72, PLA r=0.65) and without relapse. (ALA: r=0.76, PLA r=0.64). Conclusions 1. 4D TEE identified a more significant mitral annulus and leaflet remodeling in atrial fibrillation patients with relapse after initial cardioversion than in atrial fibrillation patients admitted with a first atrial fibrillation episode. 2. Mitral valve leaflets area correlated with the coaptation length. 3. Mitral annulus complex morphology in patients with atrial fibrillation could be essential in predicting relapse after initial cardioversion.Mitral annulus parameters evaluationMitral leaflets parameters evaluation

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.006
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Significance of mitral annulus apparatus morphometry in patients with persistent atrial fibrillation

R P Tudorașcu, Ionuţ Donoiu, A Craciun-Mirescu, Despina-Manuela Toader et al.
European Heart Journal
Atrial Fibrillation Management and Outcomes
article

Significance of mitral annulus apparatus morphometry in patients with persistent atrial fibrillation

R P Tudorașcu, Ionuţ Donoiu, A Craciun-Mirescu, Despina-Manuela Toader, Cristian Militaru, Monica Chițu, O Munteanu, Diana-Ruxandra Hădăreanu, M Iovanescu, C M Bezna, Sabina Florina Șolea, Octavian Istrătoaie, R Stanisor
article en

Abstract

Abstract Background Few data about mitral valve apparatus components deformation in patients with persistent atrial fibrillation are available. Four-dimensional transesophageal echocardiography (4DTEE) is an ideal imaging technique to evaluate the complex morphology of the mitral valve apparatus. Purpose The study aimed to find some characteristics in patients presenting with persistent atrial fibrillation and if some of them could be indicative of relapse after cardioversion. Methods The study enrolled 133 patients with persistent atrial fibrillation and mild/moderate functional mitral regurgitation (FMR) before cardioversion. 101 of the patients were at the first persistent atrial fibrillation episode, and 32 with relapse. After performing two-dimensional transthoracic echocardiography (2DTTE), the study included only patients with mild/moderate FMR. 4D TEE permitted a detailed examination of the mitral annulus and valve leaflets, using an E95 machine for acquisition and an ECHOPAC 204 for image postprocessing with mitral valve quantification (MVQ) software. The studied measured: annulus area (AA)3D, annulus perimeter (AP), antero-posterior diameter (APD), posteromedial-anterolateral diameter (PM-ALD), commissural diameter (CD), inter-trigonal distance (ITd), non-planar angle (NPa), mitral-aortic angle (MAa), and for the leaflets, morphological measured parameters were: anterior leaflet area (ALA), posterior leaflet area (PLA), anterior leaflet length (ALL), posterior leaflet length (PLL), anterior leaflet angle (ALa), posterior leaflet angle (PLa), tenting height (TH), tenting area (TA), tenting volume), closure line length (CLL). Results 1. We found significant statistic differences between mitral annulus apparatus components in patients with (32) and without relapse (101) after initial cardioversion: AA 3D: 3.12 vs. 11.65 (p=0.003), AP: 13.23 vs. 12.1 (p=0.0001), APD: 3.76 vs. 3.45 (p=0.0003), PM-ALD: 4.21vs 3.93 (p=0.004), CD:4.17 vs. 3.89 (p=0.002), ITd: 2.82 vs 2.74 (p=0.2), NPa: 158.5 vs 155.2 (p=0.09), MAa: 122 vs 120,7 (p=0.5), ALA: 5.73 vs. 5.18 (p=0.006), PLA: 7.04 vs. 6.09 (p < 0.0001), ALL: 2.19 vs. 2.07 (p=0.036), PLL: 1,73 vs. 1,6 (p=0.03), ALa: 15.31 vs. 18.82 (p=0.002), PLa: 21.38 vs. 25.31 (p=0.01), TH: 0.83 vs. 0.63 (p=0.001), TA: 1.63 vs. 1.32 (p=0.007), TV: 2.75 vs. 2.13 (p=0.007). 2. We found correlations between mitral valve leaflets area and coaptation length in atrial fibrillation patients with (ALA: r=0.72, PLA r=0.65) and without relapse. (ALA: r=0.76, PLA r=0.64). Conclusions 1. 4D TEE identified a more significant mitral annulus and leaflet remodeling in atrial fibrillation patients with relapse after initial cardioversion than in atrial fibrillation patients admitted with a first atrial fibrillation episode. 2. Mitral valve leaflets area correlated with the coaptation length. 3. Mitral annulus complex morphology in patients with atrial fibrillation could be essential in predicting relapse after initial cardioversion.Mitral annulus parameters evaluationMitral leaflets parameters evaluation

European Heart JournalVol. 45(Supplement_1)
University of Medicine and Pharmacy of Craiova (RO), University of Craiova (RO)
Openalex Percentile: Top 67%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.