Analysis of active impedance characteristics and harmonic deterioration of multiple grid connected inverters considering nonlinear factors

Abstract The harmonic problems caused by non‐linear factors of the grid connected inverter (GCI) system are more complicated, including both non‐characteristic harmonics emitted by the dead‐time and the changes in harmonic impedance characteristics. Harmonics interact with the changing impedance, and even cause harmonic amplification and resonance. The harmonic deterioration of the multiple GCIs system is serious. To analyse the mechanism and way of harmonic deterioration in grid‐connected system caused by nonlinear factors, the active impedance models of single inverter and multiple GCIs system including dead‐time effect and digital control delay are established first. In view of this, the influence mechanism of non‐linear factors on system stability is explored. The improved modal analysis method is used to traverse the network series parallel resonance caused by nonlinear factors. The results show that both the dead‐time effect and digital control delay reduce phase margin of the system, resulting in the resonant frequency shift and the resonant peak increase. When the harmonic excitation source interacts with the complex network under the influence of nonlinear factors, it will lead to further deterioration of harmonics. Finally, based on the MATLAB and RT‐LAB hardware‐in‐the‐loop simulation platforms, a multiple GCIs system model is built to verify the correctness of the established active impedance model and harmonic deterioration analysis.

Authors

Institutions

Publication Details

Journal
IET Renewable Power Generation
Published
2024-10-27
DOI
https://doi.org/10.1049/rpg2.13147
Citations
3
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.98

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of active impedance characteristics and harmonic deterioration of multiple grid connected inverters considering nonlinear factors

Rong Li, Jianwen Li, Wei Sun, Soyoung Song
3 citations
IET Renewable Power Generation
Microgrid Control and Optimization
0.98
article

Analysis of active impedance characteristics and harmonic deterioration of multiple grid connected inverters considering nonlinear factors

Rong Li, Jianwen Li, Wei Sun, Soyoung Song
article en
3 citations

Abstract

Abstract The harmonic problems caused by non‐linear factors of the grid connected inverter (GCI) system are more complicated, including both non‐characteristic harmonics emitted by the dead‐time and the changes in harmonic impedance characteristics. Harmonics interact with the changing impedance, and even cause harmonic amplification and resonance. The harmonic deterioration of the multiple GCIs system is serious. To analyse the mechanism and way of harmonic deterioration in grid‐connected system caused by nonlinear factors, the active impedance models of single inverter and multiple GCIs system including dead‐time effect and digital control delay are established first. In view of this, the influence mechanism of non‐linear factors on system stability is explored. The improved modal analysis method is used to traverse the network series parallel resonance caused by nonlinear factors. The results show that both the dead‐time effect and digital control delay reduce phase margin of the system, resulting in the resonant frequency shift and the resonant peak increase. When the harmonic excitation source interacts with the complex network under the influence of nonlinear factors, it will lead to further deterioration of harmonics. Finally, based on the MATLAB and RT‐LAB hardware‐in‐the‐loop simulation platforms, a multiple GCIs system model is built to verify the correctness of the established active impedance model and harmonic deterioration analysis.

IET Renewable Power GenerationVol. 18(15)
North China Electric Power University (CN), Inner Mongolia Electric Power (China) (CN)
Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 23%
Microgrid Control and Optimization
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of active impedance characteristics and harmonic deterioration of multiple grid connected inverters considering nonlinear factors — Rong Li, Jianwen Li, et al. · IET Renewable Power Generation (2024) | TGRS Research Map | TGRS