Outcomes of Radiation Dose Reduction Protocol in Electrophysiologic and Cardiac Device Procedures

Background: Exposure to radiation has been demonstrated to be associated with adverse short- and long-term health outcomes. Objective: To presented outcomes before and after the implementation of a radiation dose reduction protocol in electrophysiologic (EP) and cardiac device procedures. Materials and Methods: The present study was a retrospective comparative study, conducted at Chiang Mai University Hospital in Thailand using 2017 and 2019 data, including all patients who underwent EP and cardiac implantable electronic device (CIED) procedures. Exclusion criteria involved patients with incomplete radiation dose records. The authors compared fluoroscopic time, radiation exposure, and complication rates before and after the protocol. Results: Among the 458 cases, with 214 Eps and 244 devices, the mean age was 58 years. For device implantation procedures, there was no significant change in fluoroscopic time as median (P₂₅, P₇₅) before and after protocol implementation were 3.1 (0.4, 5.8) versus 4.4 (1.2,7.6) minutes, respectively (p=0.117). However, there was a decreasing trend in dose area product (DAP) at 242.0 (119.2, 766.0) versus 197.9 (71.5, 494.5) cGy.cm² (p=0.073). The reduction in DAP was more pronounced in cardiac resynchronization therapy (CRT) implantation when comparing 2017 to 2019 were 1,933.6 (1,039.4, 7,683.8) versus 1,074.6 (427.2, 2,890.7) cGy.cm² (p=0.020). In EP procedures, fluoroscopic time significantly decreased from 8.1 (3.0, 14.3) minutes in 2017 to 1.0 (0.0, 3.6) minute in 2019 (p<0.001), accompanied by a significant reduction in exposure dose of 45.0 (10.8, 153.3) versus 1.7 (0.0, 31.6) mGy (p<0.001) and DAP of 1,022.9 (247.2, 2,660.3) versus 38.5 (0.0, 566.9) cGy.cm² (p<0.001). There was no difference in the complication rate between the two periods. Conclusion: The implementation of the radiation dose reduction protocol resulted in a significant decrease in radiation exposure during EP procedures and showed a trend towards reduction in CIED procedures.

Publication Details

Journal
Journal of the Medical Association of Thailand
Published
2024-10-25
DOI
https://doi.org/10.35755/jmedassocthai.2024.10.771-777-825
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outcomes of Radiation Dose Reduction Protocol in Electrophysiologic and Cardiac Device Procedures

Journal of the Medical Association of Thailand
Cardiac Arrhythmias and Treatments
article

Outcomes of Radiation Dose Reduction Protocol in Electrophysiologic and Cardiac Device Procedures

article en

Abstract

Background: Exposure to radiation has been demonstrated to be associated with adverse short- and long-term health outcomes. Objective: To presented outcomes before and after the implementation of a radiation dose reduction protocol in electrophysiologic (EP) and cardiac device procedures. Materials and Methods: The present study was a retrospective comparative study, conducted at Chiang Mai University Hospital in Thailand using 2017 and 2019 data, including all patients who underwent EP and cardiac implantable electronic device (CIED) procedures. Exclusion criteria involved patients with incomplete radiation dose records. The authors compared fluoroscopic time, radiation exposure, and complication rates before and after the protocol. Results: Among the 458 cases, with 214 Eps and 244 devices, the mean age was 58 years. For device implantation procedures, there was no significant change in fluoroscopic time as median (P₂₅, P₇₅) before and after protocol implementation were 3.1 (0.4, 5.8) versus 4.4 (1.2,7.6) minutes, respectively (p=0.117). However, there was a decreasing trend in dose area product (DAP) at 242.0 (119.2, 766.0) versus 197.9 (71.5, 494.5) cGy.cm² (p=0.073). The reduction in DAP was more pronounced in cardiac resynchronization therapy (CRT) implantation when comparing 2017 to 2019 were 1,933.6 (1,039.4, 7,683.8) versus 1,074.6 (427.2, 2,890.7) cGy.cm² (p=0.020). In EP procedures, fluoroscopic time significantly decreased from 8.1 (3.0, 14.3) minutes in 2017 to 1.0 (0.0, 3.6) minute in 2019 (p<0.001), accompanied by a significant reduction in exposure dose of 45.0 (10.8, 153.3) versus 1.7 (0.0, 31.6) mGy (p<0.001) and DAP of 1,022.9 (247.2, 2,660.3) versus 38.5 (0.0, 566.9) cGy.cm² (p<0.001). There was no difference in the complication rate between the two periods. Conclusion: The implementation of the radiation dose reduction protocol resulted in a significant decrease in radiation exposure during EP procedures and showed a trend towards reduction in CIED procedures.

Journal of the Medical Association of ThailandVol. 107(10)
Good health and well-being
Openalex Percentile: Top 67%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Outcomes of Radiation Dose Reduction Protocol in Electrophysiologic and Cardiac Device Procedures · Journal of the Medical Association of Thailand (2024) | TGRS Research Map | TGRS