Robustness of Dry‐Assembled Precast Wall and Coupled Wall‐Frame High‐Rise Structures With Voided Prestressed Slabs

ABSTRACT Precast concrete structures are recognized among the structural typologies that may mostly suffer from progressive collapse as a consequence of local unpredicted damage, also due to past accidents occurred in buildings employing old precast technologies neglecting the basic robustness criteria and characterized by poorly detailed and/or executed joints and connections. Although vertical ties may relatively easily be provided in both frame and wall panel structures by employing ductile connection devices, dry‐assembled precast systems avoiding concrete pouring in the whole superstructure typically struggle to provide horizontal ties as strong as required by the current standards concerning progressive collapse, in which they are not fully framed yet. Nevertheless, these systems may exploit alternative sources of robustness to stop collapse progression arising from their structural arrangement, the shape of the slab elements employed, and the slab mechanical connections. This article presents the results of a numerical investigation focused on the structural behavior of a dry‐assembled precast floor system consisting of prestressed box‐section slab elements employed in either wall panel or coupled wall‐frame structural systems following the loss of one or multiple primary load‐bearing vertical elements. Nonlinear static simulations of different loss scenarios occurring in prototypes of 100‐m‐tall high‐rise buildings were carried out based upon spread plasticity modeling of the structural elements and experimentally calibrated nonlinear behavior of mechanical connections.

Authors

Institutions

Publication Details

Journal
The Structural Design of Tall and Special Buildings
Published
2024-10-25
DOI
https://doi.org/10.1002/tal.2189
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robustness of Dry‐Assembled Precast Wall and Coupled Wall‐Frame High‐Rise Structures With Voided Prestressed Slabs

Paolo Martinelli, Krunal Gajera, Bruno Dal Lago
The Structural Design of Tall and Special Buildings
Structural Response to Dynamic Loads
article

Robustness of Dry‐Assembled Precast Wall and Coupled Wall‐Frame High‐Rise Structures With Voided Prestressed Slabs

Paolo Martinelli, Krunal Gajera, Bruno Dal Lago
article en

Abstract

ABSTRACT Precast concrete structures are recognized among the structural typologies that may mostly suffer from progressive collapse as a consequence of local unpredicted damage, also due to past accidents occurred in buildings employing old precast technologies neglecting the basic robustness criteria and characterized by poorly detailed and/or executed joints and connections. Although vertical ties may relatively easily be provided in both frame and wall panel structures by employing ductile connection devices, dry‐assembled precast systems avoiding concrete pouring in the whole superstructure typically struggle to provide horizontal ties as strong as required by the current standards concerning progressive collapse, in which they are not fully framed yet. Nevertheless, these systems may exploit alternative sources of robustness to stop collapse progression arising from their structural arrangement, the shape of the slab elements employed, and the slab mechanical connections. This article presents the results of a numerical investigation focused on the structural behavior of a dry‐assembled precast floor system consisting of prestressed box‐section slab elements employed in either wall panel or coupled wall‐frame structural systems following the loss of one or multiple primary load‐bearing vertical elements. Nonlinear static simulations of different loss scenarios occurring in prototypes of 100‐m‐tall high‐rise buildings were carried out based upon spread plasticity modeling of the structural elements and experimentally calibrated nonlinear behavior of mechanical connections.

The Structural Design of Tall and Special BuildingsVol. 34(1)
University of Insubria (IT), Donawa Lifescience Consulting (Italy) (IT), Politecnico di Milano (IT)
Sustainable cities and communities
Openalex Percentile: Top 79%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Robustness of Dry‐Assembled Precast Wall and Coupled Wall‐Frame High‐Rise Structures With Voided Prestressed Slabs — Paolo Martinelli, Krunal Gajera, et al. · The Structural Design of Tall and Special Buildings (2024) | TGRS Research Map | TGRS