Automated, Reproducible, and Reconfigurable Human Head Phantom for Experimental Testing of Microwave Systems for Stroke Classification

ABSTRACT Microwave systems for prehospital stroke classification are currently being developed. In the future, these systems should enable rapid recognition of the type of stroke, shorten the time to start treatment, and thus significantly improve the prognosis of patients. In this study, we realized a realistic and reconfigurable 3D human head phantom for the development, testing, and validation of these newly developed diagnostic methods. The phantom enables automated and reproducible measurements for different positions of the stroke model. The stroke model itself is also interchangeable, so measurements can be made for different types, sizes, and shapes of strokes. Furthermore, an extensive series of measurements was performed at a frequency of 1 GHz, and an SVM classification algorithm was deployed, which successfully identified ischemic stroke in 80% of the corresponding measured data. If similar classification accuracy could be achieved in patients, it would lead to a dramatic reduction in the consequences of strokes.

Authors

Institutions

Publication Details

Journal
International Journal of Imaging Systems and Technology
Published
2024-10-26
DOI
https://doi.org/10.1002/ima.23200
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated, Reproducible, and Reconfigurable Human Head Phantom for Experimental Testing of Microwave Systems for Stroke Classification

Tomáš Pokorný, Tomas Drizdal, Jan Vrba, Marek Novák
2 citations
International Journal of Imaging Systems and Technology
Non-Invasive Vital Sign Monitoring
0.37
article

Automated, Reproducible, and Reconfigurable Human Head Phantom for Experimental Testing of Microwave Systems for Stroke Classification

Tomáš Pokorný, Tomas Drizdal, Jan Vrba, Marek Novák
article en
2 citations

Abstract

ABSTRACT Microwave systems for prehospital stroke classification are currently being developed. In the future, these systems should enable rapid recognition of the type of stroke, shorten the time to start treatment, and thus significantly improve the prognosis of patients. In this study, we realized a realistic and reconfigurable 3D human head phantom for the development, testing, and validation of these newly developed diagnostic methods. The phantom enables automated and reproducible measurements for different positions of the stroke model. The stroke model itself is also interchangeable, so measurements can be made for different types, sizes, and shapes of strokes. Furthermore, an extensive series of measurements was performed at a frequency of 1 GHz, and an SVM classification algorithm was deployed, which successfully identified ischemic stroke in 80% of the corresponding measured data. If similar classification accuracy could be achieved in patients, it would lead to a dramatic reduction in the consequences of strokes.

International Journal of Imaging Systems and TechnologyVol. 34(6)
Czech Technical University in Prague (CZ)
České Vysoké Učení Technické v Praze
Good health and well-being
Openalex Percentile: Top 43%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automated, Reproducible, and Reconfigurable Human Head Phantom for Experimental Testing of Microwave Systems for Stroke Classification — Tomáš Pokorný, Tomas Drizdal, et al. · International Journal of Imaging Systems and Technology (2024) | TGRS Research Map | TGRS