<i>Ex vivo</i> evaluation of the whole heart function allowing selective investigation of the right and left heart

<i>Objectives</i>. The aim was to demonstrate a reliable <i>ex vivo</i> method to test the function of the whole heart. <i>Design</i>. Pigs of varying sizes (44-80 kg) were exposed to dose response of adrenaline. Blood pressures and cardiac output were measured. The explanted hearts were tested in a novel <i>ex vivo</i> system to see if we could replicate the <i>in vivo</i> values at maximal adrenaline stimulation. The perfusion solution was STEEN Solution™ with erythrocytes and continuous infusion of essential drugs. In contrast to normal body circulation which is sequential, the heart evaluation system is divided into left and right heart circuits which are operating in parallel, making it possible to test the right and left heart individually or as a whole. The system provides coronary flow measurements. The nonlinear dynamic resistances are constructed to stabilize systolic and diastolic pressures in a broad range and independently from cardiac output. It is important for the functional evaluation to avoid pumping help for the heart; therefore, atrial vortexes are constructed to minimize pump flow directionality and energy from entering atria. <i>Results. Ex vivo</i> evaluation was able to match the maximal <i>in vivo</i> effect of adrenaline on cardiac output and blood pressures. After 2 h of evaluation, the blood gases and lactate were normal and free haemoglobin was zero. Autopsy of the hearts showed no macroscopic pathology. <i>Conclusions.</i> The system is able to give a reliable functional evaluation of the heart <i>ex vivo</i>.

Authors

Institutions

Publication Details

Journal
Scandinavian Cardiovascular Journal
Published
2024-10-26
DOI
https://doi.org/10.1080/14017431.2024.2418084
Citations
2
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ex vivo evaluation of the whole heart function allowing selective investigation of the right and left heart

Qiuming Liao, Algimantas Paškevičius, Erik Steen, Stig Steen
2 citations
Scandinavian Cardiovascular Journal
Mechanical Circulatory Support Devices
0.37
article

Ex vivo evaluation of the whole heart function allowing selective investigation of the right and left heart

Qiuming Liao, Algimantas Paškevičius, Erik Steen, Stig Steen
article en
2 citations

Abstract

<i>Objectives</i>. The aim was to demonstrate a reliable <i>ex vivo</i> method to test the function of the whole heart. <i>Design</i>. Pigs of varying sizes (44-80 kg) were exposed to dose response of adrenaline. Blood pressures and cardiac output were measured. The explanted hearts were tested in a novel <i>ex vivo</i> system to see if we could replicate the <i>in vivo</i> values at maximal adrenaline stimulation. The perfusion solution was STEEN Solution™ with erythrocytes and continuous infusion of essential drugs. In contrast to normal body circulation which is sequential, the heart evaluation system is divided into left and right heart circuits which are operating in parallel, making it possible to test the right and left heart individually or as a whole. The system provides coronary flow measurements. The nonlinear dynamic resistances are constructed to stabilize systolic and diastolic pressures in a broad range and independently from cardiac output. It is important for the functional evaluation to avoid pumping help for the heart; therefore, atrial vortexes are constructed to minimize pump flow directionality and energy from entering atria. <i>Results. Ex vivo</i> evaluation was able to match the maximal <i>in vivo</i> effect of adrenaline on cardiac output and blood pressures. After 2 h of evaluation, the blood gases and lactate were normal and free haemoglobin was zero. Autopsy of the hearts showed no macroscopic pathology. <i>Conclusions.</i> The system is able to give a reliable functional evaluation of the heart <i>ex vivo</i>.

Scandinavian Cardiovascular JournalVol. 58(1)
Lund University (SE), Skåne University Hospital (SE)
Openalex Percentile: Top 43%
Mechanical Circulatory Support Devices
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.