Effect of the method of excitation of the plasma antenna on the spectral characteristics of the radiated signal

The radiation of signal by the plasma asymmetrical vibrator antenna is studied for two methods of its excitation. Earlier, it was shown that the 2nd and 3rd harmonics of the input signal frequency in the radiation spectrum of the plasma antenna are 10—20 dB stronger than those of a metal antenna with the same geometry. In this work, we study experimentally and by computer simulations the effect of the method of excitation of the plasma asymmetrical vibrator antenna on the spectral characteristics of the signal that it radiates. For the two excitation methods of the antenna, through an electrode and through a coaxial coupler, it was shown that the strength of the signal components at the frequency of the radiated signal and its multiple harmonics is different. The introduction of the coaxial coupler in the antenna excitation scheme allowed us to improve the coupling at the input signal frequency and decrease its components at the 2nd and 3rd harmonics. For the plasma antenna with the coaxial coupler, the difference between the 1st and 2nd harmonics was increased by almost 6 dB, and between the 1st and the 3rd ones by almost 20 dB compared to the antenna excitation scheme through the electrode.

Authors

Institutions

Publication Details

Journal
Физика плазмы
Published
2024-10-26
DOI
https://doi.org/10.31857/s0367292124030073
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of the method of excitation of the plasma antenna on the spectral characteristics of the radiated signal

N. G. Guseı̆n-zade, N. N. Bogachev, M. S. Usachenok, I. L. Bogdankevich et al.
Физика плазмы
Plasma Diagnostics and Applications
article

Effect of the method of excitation of the plasma antenna on the spectral characteristics of the radiated signal

N. G. Guseı̆n-zade, N. N. Bogachev, M. S. Usachenok, I. L. Bogdankevich, S. E. Andreev
article en

Abstract

The radiation of signal by the plasma asymmetrical vibrator antenna is studied for two methods of its excitation. Earlier, it was shown that the 2nd and 3rd harmonics of the input signal frequency in the radiation spectrum of the plasma antenna are 10—20 dB stronger than those of a metal antenna with the same geometry. In this work, we study experimentally and by computer simulations the effect of the method of excitation of the plasma asymmetrical vibrator antenna on the spectral characteristics of the signal that it radiates. For the two excitation methods of the antenna, through an electrode and through a coaxial coupler, it was shown that the strength of the signal components at the frequency of the radiated signal and its multiple harmonics is different. The introduction of the coaxial coupler in the antenna excitation scheme allowed us to improve the coupling at the input signal frequency and decrease its components at the 2nd and 3rd harmonics. For the plasma antenna with the coaxial coupler, the difference between the 1st and 2nd harmonics was increased by almost 6 dB, and between the 1st and the 3rd ones by almost 20 dB compared to the antenna excitation scheme through the electrode.

Физика плазмыVol. 50(3)
National Academy of Sciences of Belarus (BY), Prokhorov General Physics Institute (RU)
Openalex Percentile: Top 83%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.