The effects of RT-qPCR standards on reproducibility and comparability in monitoring SARS-CoV-2 levels in wastewater

Reverse transcription-quantitative PCR (RT-qPCR) is widely used for monitoring viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), in wastewater. Various materials, including plasmid DNA, synthetic nucleic acids, PCR amplicons, genomic DNA, and cDNA, are currently used for SARS-CoV-2 quantification by generating standard curves. We assessed three common standards on quantifying SARS-CoV-2 RNA across nine wastewater treatment plants in Finland, as part of the national wastewater surveillance effort. We pairwise compared RT-qPCR results from 148 wastewater samples, using both IDT (#10006625, IDT, USA) and CODEX standards (#SC2-RNAC-1100, CODEX DNA), and 179 samples using both IDT and EURM019 standards (#EURM-019, European Commission, Joint Research Centre) in our assessment. Amongst the tested standards, the CODEX standard consistently yielded more stable results than either the IDT or EURM019 standards. We found that SARS-CoV-2 levels were higher with the IDT standard (4.36 Log<sub>10</sub> GC/100 mL) compared to the CODEX standard (4.05 Log<sub>10</sub> GC/100 mL). Similarly, quantification using the IDT standard was higher (5.27 Log<sub>10</sub> GC/100 mL) than values obtained with the EURM019 (4.81 Log<sub>10</sub> GC/100 mL). SARS-CoV-2 RNA quantified with IDT and CODEX standards exhibited stronger concordance (Spearman's correlation rho median of 0.79) compared to those quantified with IDT and EURM019 standards (rho median of 0.59). This study highlights the significant impact of standard material selection on SARS-CoV-2 RNA quantification, emphasizing the need for harmonization in standard material.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-26
DOI
https://doi.org/10.1038/s41598-024-77155-6
Citations
5
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
1.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effects of RT-qPCR standards on reproducibility and comparability in monitoring SARS-CoV-2 levels in wastewater

Eveliina Nurmi, Anna-Maria Hokajärvi, Aapo Juutinen, Tarja Pitkänen et al.
5 citations
Scientific Reports
SARS-CoV-2 detection and testing
1.95
article

The effects of RT-qPCR standards on reproducibility and comparability in monitoring SARS-CoV-2 levels in wastewater

Eveliina Nurmi, Anna-Maria Hokajärvi, Aapo Juutinen, Tarja Pitkänen, Ananda Tiwari, Oskari Luomala, Aleksi Kolehmainen, Anssi Lipponen, Elisa Salmivirta
article en
5 citations

Abstract

Reverse transcription-quantitative PCR (RT-qPCR) is widely used for monitoring viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), in wastewater. Various materials, including plasmid DNA, synthetic nucleic acids, PCR amplicons, genomic DNA, and cDNA, are currently used for SARS-CoV-2 quantification by generating standard curves. We assessed three common standards on quantifying SARS-CoV-2 RNA across nine wastewater treatment plants in Finland, as part of the national wastewater surveillance effort. We pairwise compared RT-qPCR results from 148 wastewater samples, using both IDT (#10006625, IDT, USA) and CODEX standards (#SC2-RNAC-1100, CODEX DNA), and 179 samples using both IDT and EURM019 standards (#EURM-019, European Commission, Joint Research Centre) in our assessment. Amongst the tested standards, the CODEX standard consistently yielded more stable results than either the IDT or EURM019 standards. We found that SARS-CoV-2 levels were higher with the IDT standard (4.36 Log<sub>10</sub> GC/100 mL) compared to the CODEX standard (4.05 Log<sub>10</sub> GC/100 mL). Similarly, quantification using the IDT standard was higher (5.27 Log<sub>10</sub> GC/100 mL) than values obtained with the EURM019 (4.81 Log<sub>10</sub> GC/100 mL). SARS-CoV-2 RNA quantified with IDT and CODEX standards exhibited stronger concordance (Spearman's correlation rho median of 0.79) compared to those quantified with IDT and EURM019 standards (rho median of 0.59). This study highlights the significant impact of standard material selection on SARS-CoV-2 RNA quantification, emphasizing the need for harmonization in standard material.

Scientific ReportsVol. 14(1)
University of Helsinki (FI), University of Eastern Finland (FI), Finnish Institute for Health and Welfare (FI), University of Oulu (FI)
Clean water and sanitation
Openalex Percentile: Top 13%
SARS-CoV-2 detection and testing
1.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.