Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29-1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-26
DOI
https://doi.org/10.1038/s41598-024-76444-4
Citations
5
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

D. Martinez, Michael R. Armstrong, Jonathan Lind, Kathryn J. Harke et al.
5 citations
Scientific Reports
Advanced X-ray Imaging Techniques
3.04
article

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

D. Martinez, Michael R. Armstrong, Jonathan Lind, Kathryn J. Harke, Mukul Kumar
article en
5 citations

Abstract

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29-1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

Scientific ReportsVol. 14(1)
Lawrence Livermore National Laboratory (US), Lawrence Livermore National Security (US)
U.S. Department of Energy, Washington State University, Office of Science, National Nuclear Security Administration, Argonne National Laboratory, Lawrence Livermore National Laboratory
Openalex Percentile: Top 9%
Advanced X-ray Imaging Techniques
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.