The dynamic of cooling heat flow of simple jersey polyester fabric

The dynamic of cooling heat flow during evaporation of the simple jersey polyester fabrics was investigated in this study. The holding period as a new parameter was introduced to study the dynamic of cooling heat flow during evaporation from the skin through the jersey knitted fabric. The holding period intervals were chosen as follows: 0, 30, 60, 90, 120, 180, 240 and 300 seconds. The Permetest skin model was used to study and visualize the dynamic of the cooling heat flow at different holding periods. Results demonstrated that adding elastane makes fabrics less cool. Three different stages were noticed concerning the cooling heat flow dynamic: the first with a maximum heat flow (Qmax) indicating the first contact properties of a textile material with the skin. The second is a transition phase where the cooling heat flow decreases to the minimum heat flow (Qmin), and then it reaches the equilibrium (Qeq) mentioning the beginning of the third stage with a constant heat flow. It was found that the holding period does not affect the measured water vapour resistance, in the case of polyester jersey fabrics.

Authors

Institutions

Publication Details

Journal
Industria Textila
Published
2024-10-24
DOI
https://doi.org/10.35530/it.075.05.202484
Primary Topic
Textile materials and evaluations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The dynamic of cooling heat flow of simple jersey polyester fabric

Sofien Benltoufa
Industria Textila
Textile materials and evaluations
article

The dynamic of cooling heat flow of simple jersey polyester fabric

Sofien Benltoufa
article en

Abstract

The dynamic of cooling heat flow during evaporation of the simple jersey polyester fabrics was investigated in this study. The holding period as a new parameter was introduced to study the dynamic of cooling heat flow during evaporation from the skin through the jersey knitted fabric. The holding period intervals were chosen as follows: 0, 30, 60, 90, 120, 180, 240 and 300 seconds. The Permetest skin model was used to study and visualize the dynamic of the cooling heat flow at different holding periods. Results demonstrated that adding elastane makes fabrics less cool. Three different stages were noticed concerning the cooling heat flow dynamic: the first with a maximum heat flow (Qmax) indicating the first contact properties of a textile material with the skin. The second is a transition phase where the cooling heat flow decreases to the minimum heat flow (Qmin), and then it reaches the equilibrium (Qeq) mentioning the beginning of the third stage with a constant heat flow. It was found that the holding period does not affect the measured water vapour resistance, in the case of polyester jersey fabrics.

Industria TextilaVol. 75(05)
University of Monastir (TN), Ecole Nationale d'Ingénieurs de Monastir
Openalex Percentile: Top 86%
Textile materials and evaluations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The dynamic of cooling heat flow of simple jersey polyester fabric — Sofien Benltoufa · Industria Textila (2024) | TGRS Research Map | TGRS