Seismic-Resistant Performance of Double Built-Up T Moment Connections

The double-T moment connection is considered in the AISC Seismic Provisions for use in steel structures subjected to seismic forces. Nowadays, the use of double-T connections requires the use of hot-rolled T-sections, which limits the optimal design. Hence, if there is a need to increase the flange or web thickness, this can only be achieved by increasing the entire T-section size, providing oversized and costly sections. In this research, this issue is addressed by studying the use of double built-up T (DBT) moment connections. Two full-scale specimens, as a complement to the five specimens previously tested by the authors, one considering a web panel zone failure mechanism and the other with the failure mechanism controlled simultaneously by the web panel zone and beam plastic hinging (balanced failure), were subjected to cyclic loading using the protocol established in AISC Seismic Provisions. Then, seven numerical models in ANSYS were developed, to reproduce the conditions of the seven specimens tested. The results showed an acceptable behavior of the specimens when the plastic hinge in the beam is the failure mechanism criterion controlling the seismic design. The specimens with a weak connection reached a lower resistance in comparison to the specimens with a weak panel zone and balanced failure. However, all specimens were able to achieve a story drift ratio of 4% with significant strength. The numerical models were calibrated from experimental data. No failures in the welds were observed in the specimens tested, which included full-penetration and fillet-welded specimens; therefore, the use of built-up T-stubs is reliable if their design is performed using a capacity design.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2024-10-26
DOI
https://doi.org/10.1061/jsendh.steng-13318
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic-Resistant Performance of Double Built-Up T Moment Connections

Ricardo Herrera, Eduardo Nuñez-Castellanos, Matías Hernández
1 citations
Journal of Structural Engineering
Structural Load-Bearing Analysis
0.26
article

Seismic-Resistant Performance of Double Built-Up T Moment Connections

Ricardo Herrera, Eduardo Nuñez-Castellanos, Matías Hernández
article en
1 citations

Abstract

The double-T moment connection is considered in the AISC Seismic Provisions for use in steel structures subjected to seismic forces. Nowadays, the use of double-T connections requires the use of hot-rolled T-sections, which limits the optimal design. Hence, if there is a need to increase the flange or web thickness, this can only be achieved by increasing the entire T-section size, providing oversized and costly sections. In this research, this issue is addressed by studying the use of double built-up T (DBT) moment connections. Two full-scale specimens, as a complement to the five specimens previously tested by the authors, one considering a web panel zone failure mechanism and the other with the failure mechanism controlled simultaneously by the web panel zone and beam plastic hinging (balanced failure), were subjected to cyclic loading using the protocol established in AISC Seismic Provisions. Then, seven numerical models in ANSYS were developed, to reproduce the conditions of the seven specimens tested. The results showed an acceptable behavior of the specimens when the plastic hinge in the beam is the failure mechanism criterion controlling the seismic design. The specimens with a weak connection reached a lower resistance in comparison to the specimens with a weak panel zone and balanced failure. However, all specimens were able to achieve a story drift ratio of 4% with significant strength. The numerical models were calibrated from experimental data. No failures in the welds were observed in the specimens tested, which included full-penetration and fillet-welded specimens; therefore, the use of built-up T-stubs is reliable if their design is performed using a capacity design.

Journal of Structural EngineeringVol. 151(1)
Universidad Católica de la Santísima Concepción (CL), University of Chile (CL)
Openalex Percentile: Top 44%
Structural Load-Bearing Analysis
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismic-Resistant Performance of Double Built-Up T Moment Connections — Ricardo Herrera, Eduardo Nuñez-Castellanos, et al. · Journal of Structural Engineering (2024) | TGRS Research Map | TGRS