Optimization of coupling phase-change materials and thermal screens in façade-integrated hybrid photovoltaic collectors for optimal energy production and thermal comfort in buildings

The operation of building-integrated photovoltaic (BIPV) systems gives rise to a significant proportion of the solar radiation absorbed by the cells being unable to be converted into electricity. This phenomenon consequently increases the temperature. This temperature increase impacts the cells' electrical efficiency, leading to a reduction in their performance and accelerating their degradation. The combination of phase-change materials with insulating fluid blades, situated behind photovoltaic cells, represents a passive cooling solution that optimizes the performance of hybrid photovoltaic systems when incorporated into facades. The present study assesses a system that incorporates paraffin as a PCM and an argon layer in a PV-PCM-argon layer physical model (PVT/ArPCM), in comparison with a PV-PCM system (PVT/PCM), to enhance the thermoelectric performance of photovoltaic systems mounted on façades while ensuring optimal thermal comfort within buildings. The discrete heat transfer equations were solved using the Thomas algorithm and the iterative Gauss-Seidel method in conjunction with the implicit finite difference method. The findings illustrate that the electrical efficiency experienced only a slight increase, estimated at 0.01%, while there was a notable enhancement in the indoor thermal comfort experienced by occupants, with a 65% improvement observed due to the incorporation of an argon-filled thermal screen. The incorporation of an argon layer led to a minor reduction in temperature of 0.01°C in the photovoltaic cells, resulting in a minimal improvement of 0.014% in electrical power production. The phase-changing material incorporated into PVT/ArPCM demonstrated superior thermal management capabilities in comparison to the same material employed in PVT/PCM.

Authors

Institutions

Publication Details

Journal
Edelweiss Applied Science and Technology
Published
2024-10-25
DOI
https://doi.org/10.55214/25768484.v8i6.2558
Citations
2
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of coupling phase-change materials and thermal screens in façade-integrated hybrid photovoltaic collectors for optimal energy production and thermal comfort in buildings

Yawovi Nougbléga, Kodjo Kpodé, Yendoubé Lare, Kokou Aménuvéla Toka
2 citations
Edelweiss Applied Science and Technology
Solar Thermal and Photovoltaic Systems
0.20
article

Optimization of coupling phase-change materials and thermal screens in façade-integrated hybrid photovoltaic collectors for optimal energy production and thermal comfort in buildings

Yawovi Nougbléga, Kodjo Kpodé, Yendoubé Lare, Kokou Aménuvéla Toka
article en
2 citations

Abstract

The operation of building-integrated photovoltaic (BIPV) systems gives rise to a significant proportion of the solar radiation absorbed by the cells being unable to be converted into electricity. This phenomenon consequently increases the temperature. This temperature increase impacts the cells' electrical efficiency, leading to a reduction in their performance and accelerating their degradation. The combination of phase-change materials with insulating fluid blades, situated behind photovoltaic cells, represents a passive cooling solution that optimizes the performance of hybrid photovoltaic systems when incorporated into facades. The present study assesses a system that incorporates paraffin as a PCM and an argon layer in a PV-PCM-argon layer physical model (PVT/ArPCM), in comparison with a PV-PCM system (PVT/PCM), to enhance the thermoelectric performance of photovoltaic systems mounted on façades while ensuring optimal thermal comfort within buildings. The discrete heat transfer equations were solved using the Thomas algorithm and the iterative Gauss-Seidel method in conjunction with the implicit finite difference method. The findings illustrate that the electrical efficiency experienced only a slight increase, estimated at 0.01%, while there was a notable enhancement in the indoor thermal comfort experienced by occupants, with a 65% improvement observed due to the incorporation of an argon-filled thermal screen. The incorporation of an argon layer led to a minor reduction in temperature of 0.01°C in the photovoltaic cells, resulting in a minimal improvement of 0.014% in electrical power production. The phase-changing material incorporated into PVT/ArPCM demonstrated superior thermal management capabilities in comparison to the same material employed in PVT/PCM.

Edelweiss Applied Science and TechnologyVol. 8(6)
University of Kara (TG), University of Lomé (TG)
Affordable and clean energy
Openalex Percentile: Top 57%
Solar Thermal and Photovoltaic Systems
0.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.