A hybrid experimental configuration for emissivity measurement at cryogenic temperatures

Abstract In cryogenic and high vacuum systems, radiation mode of heat transfer is the primary source of energy interaction owing to the wide temperature differentials and very low temperatures and pressures. Measurement of radiative properties such as emissivity is crucial in the design of cryogenic systems. Emissivity measurement at cryogenic temperatures requires careful consideration of the sample preparation and measurement conditions to ensure accuracy and reliability. Most experimental techniques developed so far are complex in their design and equipment, and they work only on a single measuring method. To address these challenges, this research has proposed a simpler and hybrid experimental setup that could employ both calorimetric and heat flux methods to directly measure the total hemispherical emissivity in the range 90 K–180 K. Experiments were conducted with five types of materials (black paint, stainless steel, aluminum foil, aluminized mylar foil, and copper sheet) by using both methods, and the results were validated with the literature data. The data obtained by calorimetric and heat flux methods for each sample showed a high level of consistency with each other, with a variation of only ±1.5%. Moreover, the discrepancy between the measured and literature data was within the acceptable range of 0.3%–10%. The total hemispherical emissivity of mechanically treated copper was higher than that of chemically polished copper by 11%. This simplified setup has incorporated all possible means to minimize heat leakages into and from the cryostat while maintaining accuracy. The obtained data can be used to accurately estimate the radiation heat loads in cryopumps and other cryogenic systems that use similar components.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2024-10-24
DOI
https://doi.org/10.1088/1402-4896/ad86fd
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hybrid experimental configuration for emissivity measurement at cryogenic temperatures

Manu M. John, Rijo Jacob Thomas, K. A. Shafi
Physica Scripta
Thermal Radiation and Cooling Technologies
article

A hybrid experimental configuration for emissivity measurement at cryogenic temperatures

Manu M. John, Rijo Jacob Thomas, K. A. Shafi
article en

Abstract

Abstract In cryogenic and high vacuum systems, radiation mode of heat transfer is the primary source of energy interaction owing to the wide temperature differentials and very low temperatures and pressures. Measurement of radiative properties such as emissivity is crucial in the design of cryogenic systems. Emissivity measurement at cryogenic temperatures requires careful consideration of the sample preparation and measurement conditions to ensure accuracy and reliability. Most experimental techniques developed so far are complex in their design and equipment, and they work only on a single measuring method. To address these challenges, this research has proposed a simpler and hybrid experimental setup that could employ both calorimetric and heat flux methods to directly measure the total hemispherical emissivity in the range 90 K–180 K. Experiments were conducted with five types of materials (black paint, stainless steel, aluminum foil, aluminized mylar foil, and copper sheet) by using both methods, and the results were validated with the literature data. The data obtained by calorimetric and heat flux methods for each sample showed a high level of consistency with each other, with a variation of only ±1.5%. Moreover, the discrepancy between the measured and literature data was within the acceptable range of 0.3%–10%. The total hemispherical emissivity of mechanically treated copper was higher than that of chemically polished copper by 11%. This simplified setup has incorporated all possible means to minimize heat leakages into and from the cryostat while maintaining accuracy. The obtained data can be used to accurately estimate the radiation heat loads in cryopumps and other cryogenic systems that use similar components.

Physica ScriptaVol. 99(11)
APJ Abdul Kalam Technological University (IN)
Affordable and clean energy
Openalex Percentile: Top 79%
Thermal Radiation and Cooling Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A hybrid experimental configuration for emissivity measurement at cryogenic temperatures — Manu M. John, Rijo Jacob Thomas, et al. · Physica Scripta (2024) | TGRS Research Map | TGRS