The effect of the floor-wall interaction on the post-elastic rocking behaviour of segmented CLT shear walls

This paper investigates the impact of floor-wall interaction on the lateral rocking behaviour of two-panel segmented Cross-Laminated Timber (CLT) shear walls through experimental testing and numerical analyses. The study extends a simplified equivalent spring modelling approach to the post-elastic domain to accurately simulate the effects of floor-wall interaction. Experimental withdrawal tests on four types of floor-to-wall connections, utilizing Fully Threaded Screws (FTSs) and Partially Threaded Screws (PTSs) at varying inclinations, revealed that FTSs exhibited higher stiffness and load-carrying capacity but lower deformation capacity compared to PTSs. The maximum force of FTS connections was about twice that of PTS connections, while PTS connections achieved ultimate displacements up to seven times greater. Numerical analyses using a parametric framework showed that floor-wall interaction increases the stiffness and lateral load-carrying capacity of segmented shear walls, with a significant reduction in deformation capacity. These analyses also demonstrated that the equivalent spring can effectively replicate the influence of floor-wall interaction on shear wall lateral response. Expressions for calculating the strength and ductility of this equivalent spring were developed, considering a limited set of geometric and mechanical parameters. These expressions provide a simplified yet accurate method for estimating the effects of floor-wall interaction. The findings suggest that understanding the interaction between floor and wall elements is crucial for optimizing the performance of segmented CLT shear walls in seismic and lateral load scenarios. • The effect of the floor-wall interaction on the post-elastic rocking behaviour of segmented CLT shear walls is investigated. • Experimental tests on typical screwed CLT floor-to-wall connections are carried out. • Numerical parametric analyses at floor and wall level are conducted. • A simplified non-linear equivalent spring is proposed to simulate the floor-wall interaction mechanism.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2024-10-25
DOI
https://doi.org/10.1016/j.engstruct.2024.119212
Citations
2
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of the floor-wall interaction on the post-elastic rocking behaviour of segmented CLT shear walls

Giuseppe D’Arenzo, Werner Seim
2 citations
Engineering Structures
Masonry and Concrete Structural Analysis
0.52
article

The effect of the floor-wall interaction on the post-elastic rocking behaviour of segmented CLT shear walls

Giuseppe D’Arenzo, Werner Seim
article en
2 citations

Abstract

This paper investigates the impact of floor-wall interaction on the lateral rocking behaviour of two-panel segmented Cross-Laminated Timber (CLT) shear walls through experimental testing and numerical analyses. The study extends a simplified equivalent spring modelling approach to the post-elastic domain to accurately simulate the effects of floor-wall interaction. Experimental withdrawal tests on four types of floor-to-wall connections, utilizing Fully Threaded Screws (FTSs) and Partially Threaded Screws (PTSs) at varying inclinations, revealed that FTSs exhibited higher stiffness and load-carrying capacity but lower deformation capacity compared to PTSs. The maximum force of FTS connections was about twice that of PTS connections, while PTS connections achieved ultimate displacements up to seven times greater. Numerical analyses using a parametric framework showed that floor-wall interaction increases the stiffness and lateral load-carrying capacity of segmented shear walls, with a significant reduction in deformation capacity. These analyses also demonstrated that the equivalent spring can effectively replicate the influence of floor-wall interaction on shear wall lateral response. Expressions for calculating the strength and ductility of this equivalent spring were developed, considering a limited set of geometric and mechanical parameters. These expressions provide a simplified yet accurate method for estimating the effects of floor-wall interaction. The findings suggest that understanding the interaction between floor and wall elements is crucial for optimizing the performance of segmented CLT shear walls in seismic and lateral load scenarios. • The effect of the floor-wall interaction on the post-elastic rocking behaviour of segmented CLT shear walls is investigated. • Experimental tests on typical screwed CLT floor-to-wall connections are carried out. • Numerical parametric analyses at floor and wall level are conducted. • A simplified non-linear equivalent spring is proposed to simulate the floor-wall interaction mechanism.

Engineering StructuresVol. 322
University of Kassel (DE), Aarhus University (DK), Aarhus School of Architecture (DK), Shanghai Xiandai Architectural Design (CN)
Universität Kassel
Sustainable cities and communities
Openalex Percentile: Top 35%
Masonry and Concrete Structural Analysis
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.