First experience of implantation of a new-generation bioresorbable stent in a young patient with coronary artery disease: a case report

Implantation of a drug-eluting stent into the area of hemodynamically significant coronary artery lesion is a generally accepted and widespread method of coronary artery disease (CAD) treatment. However, rigid metallic frame in artery is associated with disrupted vascular biomechanics and neointimal proliferation in response to foreign material. These processes can lead to restenosis and/or late thrombosis of the implanted stent and, as a consequence, to the recurrence of CAD symptoms, as well as to adverse cardiovascular events. One of the options for solving the above problems is the implantation of bioresorbable stents. This technique already has an evidence base and is increasingly being introduced into routine clinical practice in certain groups of patients. The article presents a case of successful balloon angioplasty and stenting of the right coronary artery with a new-generation bioresorbable stent in a young patient with CAD.

Authors

Publication Details

Journal
CARDIOVASCULAR THERAPY AND PREVENTION
Published
2024-10-23
DOI
https://doi.org/10.15829/1728-8800-2024-4196
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First experience of implantation of a new-generation bioresorbable stent in a young patient with coronary artery disease: a case report

N. A. Arablinsky, D. К. Vasiliev, M. T. Taliuridze, F. B. Shukurov et al.
CARDIOVASCULAR THERAPY AND PREVENTION
Coronary Interventions and Diagnostics
article

First experience of implantation of a new-generation bioresorbable stent in a young patient with coronary artery disease: a case report

N. A. Arablinsky, D. К. Vasiliev, M. T. Taliuridze, F. B. Shukurov, D. A. Feshchenko, А. S. Shanoyan
article en

Abstract

Implantation of a drug-eluting stent into the area of hemodynamically significant coronary artery lesion is a generally accepted and widespread method of coronary artery disease (CAD) treatment. However, rigid metallic frame in artery is associated with disrupted vascular biomechanics and neointimal proliferation in response to foreign material. These processes can lead to restenosis and/or late thrombosis of the implanted stent and, as a consequence, to the recurrence of CAD symptoms, as well as to adverse cardiovascular events. One of the options for solving the above problems is the implantation of bioresorbable stents. This technique already has an evidence base and is increasingly being introduced into routine clinical practice in certain groups of patients. The article presents a case of successful balloon angioplasty and stenting of the right coronary artery with a new-generation bioresorbable stent in a young patient with CAD.

CARDIOVASCULAR THERAPY AND PREVENTIONVol. 23(9)
Good health and well-being
Openalex Percentile: Top 64%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

First experience of implantation of a new-generation bioresorbable stent in a young patient with coronary artery disease: a case report — N. A. Arablinsky, D. К. Vasiliev, et al. · CARDIOVASCULAR THERAPY AND PREVENTION (2024) | TGRS Research Map | TGRS