An early economic evaluation of WireSafe™ to prevent guidewire retention in central venous catheter procedures

Background Guidewire retention (GWR) poses a patient safety risk during Central Venous Catheter (CVC) insertions and is listed as a ‘Never Event’ by the National Health Service England (NHSE). WireSafe™ is an intervention to prevent GWR, but its cost-effectiveness is uncertain. This study is an early economic evaluation comparing WireSafe™ to standard care from a UK healthcare perspective. Methods We conducted (i) a primary analysis of GWR related NHSE Never Events data in England between 2016 and 2020; and (ii) a cost-utility analysis, including healthcare costs and quality-adjusted life years (QALYS) for populations receiving CVC-insertions. We applied a cost-effectiveness threshold of £30,000 per QALY and considered three WireSafe™ costing scenarios (£18.50, £4.50, and £2.50). Results NHSE Never Events data showed 61 GWR cases, averaging 1 per month. Most incidents (92%) were identified during hospital stays, with one serious adverse outcome reported (peri-arrest). In a population of 200,000, we estimate WireSafe™ would prevent 59.92 wire retentions, 5.61 procedural adverse events, 0.3 cardiac adverse events, and 0.19 deaths, improving QALYs by 4.87. In the base case analysis WireSafe™ was not cost-effective and had an economically justifiable price of £2.44. There were high levels of uncertainty in the lowest cost-scenario (ICER 95% credible interval: Dominant; £793,398). Conclusions The health benefits of WireSafe™ are limited due to low GWR rates and high identification rates, making WireSafe™ viable only at low costs. Future research should prioritise obtaining more precise estimates of these parameter values which are key determinants of cost-effectiveness.

Authors

Institutions

Publication Details

Journal
Journal of Patient Safety and Risk Management
Published
2024-10-25
DOI
https://doi.org/10.1177/25160435241292699
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An early economic evaluation of WireSafe™ to prevent guidewire retention in central venous catheter procedures

Richard Mattock, Rebecca Lawton, AM Hanbury, Matthew Morys‐Edge
Journal of Patient Safety and Risk Management
Central Venous Catheters and Hemodialysis
article

An early economic evaluation of WireSafe™ to prevent guidewire retention in central venous catheter procedures

Richard Mattock, Rebecca Lawton, AM Hanbury, Matthew Morys‐Edge
article en

Abstract

Background Guidewire retention (GWR) poses a patient safety risk during Central Venous Catheter (CVC) insertions and is listed as a ‘Never Event’ by the National Health Service England (NHSE). WireSafe™ is an intervention to prevent GWR, but its cost-effectiveness is uncertain. This study is an early economic evaluation comparing WireSafe™ to standard care from a UK healthcare perspective. Methods We conducted (i) a primary analysis of GWR related NHSE Never Events data in England between 2016 and 2020; and (ii) a cost-utility analysis, including healthcare costs and quality-adjusted life years (QALYS) for populations receiving CVC-insertions. We applied a cost-effectiveness threshold of £30,000 per QALY and considered three WireSafe™ costing scenarios (£18.50, £4.50, and £2.50). Results NHSE Never Events data showed 61 GWR cases, averaging 1 per month. Most incidents (92%) were identified during hospital stays, with one serious adverse outcome reported (peri-arrest). In a population of 200,000, we estimate WireSafe™ would prevent 59.92 wire retentions, 5.61 procedural adverse events, 0.3 cardiac adverse events, and 0.19 deaths, improving QALYs by 4.87. In the base case analysis WireSafe™ was not cost-effective and had an economically justifiable price of £2.44. There were high levels of uncertainty in the lowest cost-scenario (ICER 95% credible interval: Dominant; £793,398). Conclusions The health benefits of WireSafe™ are limited due to low GWR rates and high identification rates, making WireSafe™ viable only at low costs. Future research should prioritise obtaining more precise estimates of these parameter values which are key determinants of cost-effectiveness.

Journal of Patient Safety and Risk ManagementVol. 29(6)
University of Leeds (GB), Calderdale and Huddersfield NHS Foundation Trust (GB)
National Institute for Health and Care Research
Openalex Percentile: Top 67%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.