Structural performance of split orthogonal beam joints in continuous beam‐type circular concrete‐filled steel tubular beam‐to‐column connections

Abstract A continuous beam‐type connection has been proposed as a new type of concrete‐filled steel tubular beam‐to‐column connection without a diaphragm exhibits good seismic performance. However, in a 2‐way configuration, the performance of the connection in a direction orthogonal to the continuous beam may be suboptimal due to beam splitting. In this study, a new detail of a split orthogonal beam joint was proposed and 4 specimens were constructed and tested under quasi‐static conditions. All the specimens attained the full‐plastic flexural strength for the beams and exhibited a stable inelastic behavior. The specimen in which the depth of the orthogonal continuous beam was 100 mm greater than that of the split beam exhibited good inelastic cyclic behavior, whereas two other specimens with a split beam exhibited slipping and pinching. Minor fractures were observed in the tube wall; however, the strength and stiffness did not deteriorate significantly, though a slight pinched hysteresis was observed. In addition, a finite element analysis was conducted. The split beam was largely rotationally constrained by the bearing pressure of the concrete above and/or below the beam flange. If the split beam's flange was sufficiently inserted into the connection panel, the stiffness and strength were ensured.

Authors

Institutions

Publication Details

Journal
Japan Architectural Review
Published
2024-10-25
DOI
https://doi.org/10.1002/2475-8876.70006
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural performance of split orthogonal beam joints in continuous beam‐type circular concrete‐filled steel tubular beam‐to‐column connections

Noritaka Ando, Takashi Fujinaga
Japan Architectural Review
Structural Load-Bearing Analysis
article

Structural performance of split orthogonal beam joints in continuous beam‐type circular concrete‐filled steel tubular beam‐to‐column connections

Noritaka Ando, Takashi Fujinaga
article en

Abstract

Abstract A continuous beam‐type connection has been proposed as a new type of concrete‐filled steel tubular beam‐to‐column connection without a diaphragm exhibits good seismic performance. However, in a 2‐way configuration, the performance of the connection in a direction orthogonal to the continuous beam may be suboptimal due to beam splitting. In this study, a new detail of a split orthogonal beam joint was proposed and 4 specimens were constructed and tested under quasi‐static conditions. All the specimens attained the full‐plastic flexural strength for the beams and exhibited a stable inelastic behavior. The specimen in which the depth of the orthogonal continuous beam was 100 mm greater than that of the split beam exhibited good inelastic cyclic behavior, whereas two other specimens with a split beam exhibited slipping and pinching. Minor fractures were observed in the tube wall; however, the strength and stiffness did not deteriorate significantly, though a slight pinched hysteresis was observed. In addition, a finite element analysis was conducted. The split beam was largely rotationally constrained by the bearing pressure of the concrete above and/or below the beam flange. If the split beam's flange was sufficiently inserted into the connection panel, the stiffness and strength were ensured.

Japan Architectural ReviewVol. 8(1)
Kobe University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 79%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.