The Impact of Pneumoperitoneum on Mean Expiratory Flow Rate: Observational Insights from Patients with Healthy Lungs

A PP of 20 cmH<sub>2</sub>O resulted in an increase in the mean expiratory flow rate in the conventional I:E ratio in the volume-ventilated mode. PP reduces lung and chest wall compliance by elevating the diaphragm, compressing the thoracic cavity, and increasing airway pressures. Consequently, the lungs and chest wall stiffen, requiring greater ventilatory effort and accelerating expiratory flow due to increased airway resistance and altered pulmonary mechanics. Prolonging the inspiratory phase through I:E ratio adjustment helps maintain peak inspiratory pressures closer to baseline levels, and this method enhances the safety and efficacy of mechanical ventilation in maintaining optimal respiratory function during laparoscopic surgery.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-10-24
DOI
https://doi.org/10.3390/diagnostics14212375
Citations
4
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
2.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Pneumoperitoneum on Mean Expiratory Flow Rate: Observational Insights from Patients with Healthy Lungs

Balázs Sütő, Csaba Csontos, Lajos Bogár, Kamilla Domokos
4 citations
Diagnostics
Hemodynamic Monitoring and Therapy
2.29
article

The Impact of Pneumoperitoneum on Mean Expiratory Flow Rate: Observational Insights from Patients with Healthy Lungs

Balázs Sütő, Csaba Csontos, Lajos Bogár, Kamilla Domokos
article en
4 citations

Abstract

A PP of 20 cmH<sub>2</sub>O resulted in an increase in the mean expiratory flow rate in the conventional I:E ratio in the volume-ventilated mode. PP reduces lung and chest wall compliance by elevating the diaphragm, compressing the thoracic cavity, and increasing airway pressures. Consequently, the lungs and chest wall stiffen, requiring greater ventilatory effort and accelerating expiratory flow due to increased airway resistance and altered pulmonary mechanics. Prolonging the inspiratory phase through I:E ratio adjustment helps maintain peak inspiratory pressures closer to baseline levels, and this method enhances the safety and efficacy of mechanical ventilation in maintaining optimal respiratory function during laparoscopic surgery.

DiagnosticsVol. 14(21)
University of Pecs (HU)
Openalex Percentile: Top 11%
Hemodynamic Monitoring and Therapy
2.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.