Automated Breast Density Assessment for Full-Field Digital Mammography and Digital Breast Tomosynthesis

Mammographic density is a strong risk factor for breast cancer and is reported clinically as part of Breast Imaging Reporting and Data System (BI-RADS) results issued by radiologists. Automated assessment of density is needed that can be used for both full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) as both types of exams are acquired in standard clinical practice. We trained a deep learning model to automate the estimation of BI-RADS density from a prospective Washington University clinic-based cohort of 9,714 women, entering into the cohort in 2013 with follow-up through October 31, 2020. The cohort included 27% non-Hispanic Black women. The trained algorithm was assessed in an external validation cohort that included 18,360 women screened at Emory from January 1, 2013, and followed up through December 31, 2020, that included 42% non-Hispanic Black women. Our model-estimated BI-RADS density demonstrated substantial agreement with the density as assessed by radiologists. In the external validation, the agreement with radiologists for category B 81% and C 77% for FFDM and B 83% and C 74% for DBT shows important distinction for separation of women with dense breast. We obtained a Cohen's κ of 0.72 (95% confidence interval, 0.71-0.73) in FFDM and 0.71 (95% confidence interval, 0.69-0.73) in DBT. We provided a consistent and fully automated BI-RADS estimation for both FFDM and DBT using a deep learning model. The software can be easily implemented anywhere for clinical use and risk prediction. Prevention Relevance: The proposed model can reduce interobserver variability in BI-RADS density assessment, thereby providing more standard and consistent density assessment for use in decisions about supplemental screening and risk assessment.

Authors

Institutions

Publication Details

Journal
Cancer Prevention Research
Published
2024-10-25
DOI
https://doi.org/10.1158/1940-6207.capr-24-0338
Citations
3
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
1.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Breast Density Assessment for Full-Field Digital Mammography and Digital Breast Tomosynthesis

Simin Chen, Graham A. Colditz, Debbie L. Bennett, Shu Jiang et al.
3 citations
Cancer Prevention Research
Digital Radiography and Breast Imaging
1.26
article

Automated Breast Density Assessment for Full-Field Digital Mammography and Digital Breast Tomosynthesis

Simin Chen, Graham A. Colditz, Debbie L. Bennett, Shu Jiang, Adetunji T. Toriola
article en
3 citations

Abstract

Mammographic density is a strong risk factor for breast cancer and is reported clinically as part of Breast Imaging Reporting and Data System (BI-RADS) results issued by radiologists. Automated assessment of density is needed that can be used for both full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) as both types of exams are acquired in standard clinical practice. We trained a deep learning model to automate the estimation of BI-RADS density from a prospective Washington University clinic-based cohort of 9,714 women, entering into the cohort in 2013 with follow-up through October 31, 2020. The cohort included 27% non-Hispanic Black women. The trained algorithm was assessed in an external validation cohort that included 18,360 women screened at Emory from January 1, 2013, and followed up through December 31, 2020, that included 42% non-Hispanic Black women. Our model-estimated BI-RADS density demonstrated substantial agreement with the density as assessed by radiologists. In the external validation, the agreement with radiologists for category B 81% and C 77% for FFDM and B 83% and C 74% for DBT shows important distinction for separation of women with dense breast. We obtained a Cohen's κ of 0.72 (95% confidence interval, 0.71-0.73) in FFDM and 0.71 (95% confidence interval, 0.69-0.73) in DBT. We provided a consistent and fully automated BI-RADS estimation for both FFDM and DBT using a deep learning model. The software can be easily implemented anywhere for clinical use and risk prediction. Prevention Relevance: The proposed model can reduce interobserver variability in BI-RADS density assessment, thereby providing more standard and consistent density assessment for use in decisions about supplemental screening and risk assessment.

Cancer Prevention ResearchVol. 18(1)
Washington University in St. Louis (US), Jewish Hospital (US)
National Cancer Institute
Good health and well-being
Openalex Percentile: Top 18%
Digital Radiography and Breast Imaging
1.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.