Comparative Evaluation of Osseointegration Parameters between Titanium and Zirconia Implants Placed in Beagle Dogs

Purpose: Endosseous titanium dental implants are widely regarded as the gold standard for replacing missing teeth.Despite the proven osseointegration of titanium implants, particularly those with enhanced surface modifications, concerns remain regarding esthetics, the risk of peri-implantitis, and potential hypersensitivity.Consequently, alternative materials, such as zirconia, have received increasing attention in recent years.This study evaluated the osseointegration parameters of zirconia implants placed in the mandibles of beagle dogs, as a preliminary in vivo evaluation of zirconia dental implants in South Korea.Materials and Methods: Seven 8-month-old beagle dogs underwent premolar extraction followed by placement of implants in the healed mandibular ridges.The following implants were used in this study: six turned-surface titanium implants, six rough-surface titanium implants, and six zirconia implants, following which the implants and surrounding tissues were harvested en bloc for histological analyses.Bone-to-implant contact (BIC) and new bone area (BA) percentages (%) were calculated and compared between the groups.Statistical analyses were conducted using ANOVA, with the significance level set at p < .05.Results: Histological analysis revealed no statistically significant difference in BIC between the rough-surface titanium and zirconia implants, although the turned-surface titanium implants exhibited significantly lower BIC than the other two groups (p < .05).No significant differences were found among the three groups in terms of BA. Conclusion:The results of this study demonstrate that zirconia implants achieve BIC comparable to that of rough-surface titanium implants, suggestive of their potential clinical application.

Authors

Publication Details

Journal
Journal of implantology and applied sciences
Published
2024-09-30
DOI
https://doi.org/10.32542/implantology.2024014
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Osseointegration Parameters between Titanium and Zirconia Implants Placed in Beagle Dogs

In‐Sung Yeo, Yang‐Jo Seol, Kihyun Kim, Jun‐Beom Lee et al.
Journal of implantology and applied sciences
Dental Implant Techniques and Outcomes
article

Comparative Evaluation of Osseointegration Parameters between Titanium and Zirconia Implants Placed in Beagle Dogs

In‐Sung Yeo, Yang‐Jo Seol, Kihyun Kim, Jun‐Beom Lee, N. Luong
article en

Abstract

Purpose: Endosseous titanium dental implants are widely regarded as the gold standard for replacing missing teeth.Despite the proven osseointegration of titanium implants, particularly those with enhanced surface modifications, concerns remain regarding esthetics, the risk of peri-implantitis, and potential hypersensitivity.Consequently, alternative materials, such as zirconia, have received increasing attention in recent years.This study evaluated the osseointegration parameters of zirconia implants placed in the mandibles of beagle dogs, as a preliminary in vivo evaluation of zirconia dental implants in South Korea.Materials and Methods: Seven 8-month-old beagle dogs underwent premolar extraction followed by placement of implants in the healed mandibular ridges.The following implants were used in this study: six turned-surface titanium implants, six rough-surface titanium implants, and six zirconia implants, following which the implants and surrounding tissues were harvested en bloc for histological analyses.Bone-to-implant contact (BIC) and new bone area (BA) percentages (%) were calculated and compared between the groups.Statistical analyses were conducted using ANOVA, with the significance level set at p < .05.Results: Histological analysis revealed no statistically significant difference in BIC between the rough-surface titanium and zirconia implants, although the turned-surface titanium implants exhibited significantly lower BIC than the other two groups (p < .05).No significant differences were found among the three groups in terms of BA. Conclusion:The results of this study demonstrate that zirconia implants achieve BIC comparable to that of rough-surface titanium implants, suggestive of their potential clinical application.

Journal of implantology and applied sciencesVol. 28(3)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea
Life below water
Openalex Percentile: Top 71%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.