Assessing the criterion validity of the activPAL CREA v1.3 algorithm and ActiPASS 2023.12 software for detecting steps during a progressive treadmill-based laboratory protocol

Thigh-worn accelerometry is commonly implemented to measure step cadence. The default activPAL CREA algorithm is a valid measure of cadence during walking, but its validity during running is unknown. The ActiPASS software is designed to analyse tri-axial accelerometry data from various brands. We tested the validity of CREA v1.3 and ActiPASS 2023.12 to measure step cadence against manually-counted steps. Forty-five participants (26♀, 23.4 ± 4.6 years) completed 5 walking (6 min each, 2-4 mph) and 5 running treadmill (5-7 mph) stages (423 total stages completed). Based on equivalence testing, walking cadence (stages 1-5: 92-124 steps/min) from CREA was statistically equivalent (zone: <±2.2% of the manually-counted mean) to manual counts (92-125 steps/min). However, CREA underpredicted cadence during running stages (stages 6-10: 143-135 steps/min) by ~ 11-20 steps/min (<i>p</i> < 0.001). The ActiPASS-derived cadences were equivalent (zone: <±3.3%) to manual counts for all walking stages (99-127 steps/min) except Stage 1 (zone: ±10.5%). ActiPASS underpredicted cadences during running (stages 6-10: 137-153 steps/min) by ~ 10-16 steps/min (<i>p</i> < 0.001) compared to manual counts (stages 6-10: 154-164 steps/min). The CREA v1.3 algorithm is a valid measure of cadence during walking while ActiPASS 2023.12 is a valid measure of cadence during medium-fast walking. Further research is required to improve step cadence estimation across ambulation speeds.

Authors

Institutions

Publication Details

Journal
Journal of Sports Sciences
Published
2024-10-17
DOI
https://doi.org/10.1080/02640414.2024.2419222
Citations
1
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the criterion validity of the activPAL CREA v1.3 algorithm and ActiPASS 2023.12 software for detecting steps during a progressive treadmill-based laboratory protocol

Madeline E. Shivgulam, Molly K. Courish, Liam P. Pellerine, Derek S. Kimmerly et al.
1 citations
Journal of Sports Sciences
Hemodynamic Monitoring and Therapy
0.57
article

Assessing the criterion validity of the activPAL CREA v1.3 algorithm and ActiPASS 2023.12 software for detecting steps during a progressive treadmill-based laboratory protocol

Madeline E. Shivgulam, Molly K. Courish, Liam P. Pellerine, Derek S. Kimmerly, Pasan Hettiarachchi, Peter Johansson, Jennifer L. Petterson, Myles W. O’Brien
article en
1 citations

Abstract

Thigh-worn accelerometry is commonly implemented to measure step cadence. The default activPAL CREA algorithm is a valid measure of cadence during walking, but its validity during running is unknown. The ActiPASS software is designed to analyse tri-axial accelerometry data from various brands. We tested the validity of CREA v1.3 and ActiPASS 2023.12 to measure step cadence against manually-counted steps. Forty-five participants (26♀, 23.4 ± 4.6 years) completed 5 walking (6 min each, 2-4 mph) and 5 running treadmill (5-7 mph) stages (423 total stages completed). Based on equivalence testing, walking cadence (stages 1-5: 92-124 steps/min) from CREA was statistically equivalent (zone: <±2.2% of the manually-counted mean) to manual counts (92-125 steps/min). However, CREA underpredicted cadence during running stages (stages 6-10: 143-135 steps/min) by ~ 11-20 steps/min (<i>p</i> < 0.001). The ActiPASS-derived cadences were equivalent (zone: <±3.3%) to manual counts for all walking stages (99-127 steps/min) except Stage 1 (zone: ±10.5%). ActiPASS underpredicted cadences during running (stages 6-10: 137-153 steps/min) by ~ 10-16 steps/min (<i>p</i> < 0.001) compared to manual counts (stages 6-10: 154-164 steps/min). The CREA v1.3 algorithm is a valid measure of cadence during walking while ActiPASS 2023.12 is a valid measure of cadence during medium-fast walking. Further research is required to improve step cadence estimation across ambulation speeds.

Journal of Sports SciencesVol. 42(20)
Uppsala University (SE), Dalhousie University (CA), Uppsala University Hospital (SE)
Health Research, Dalhousie University
Openalex Percentile: Top 28%
Hemodynamic Monitoring and Therapy
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.