Primary realization of spectral responsivity in the near infrared using a laser-driven light source
Abstract The National Research Council (NRC) Canada has realized the spectral responsivity scale from 900 nm to 1600 nm using a Xe-based laser driven light source, double subtractive monochromator system, and an absolute cryogenic radiometer. An NRC-designed InGaAs sphere transfer standard radiometer was calibrated with combined relative standard uncertainties below 0.135 % (k=1). The scale realization was also performed with a 100 W tungsten lamp, as previously done at NRC. Calibration results and uncertainties in spectral responsivity measurements with each broadband light source are compared and presented.
Authors
- Angela Gamouras (ORCID: https://orcid.org/0000-0003-0378-806X)
Institutions
- National Research Council Canada (CA)
Publication Details
- Journal
- Journal of Physics Conference Series
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1088/1742-6596/2864/1/012003
- Primary Topic
- Calibration and Measurement Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00