Realization of (400∼950) nm detector-based spectral radiance scale at NIM

Abstract Detector-based radiometric measurement is advantageous in terms of measurement uncertainty. National Institute of Metrology China (NIM) has developed a facility for detector-based spectral radiance scale realization in the range of (400∼950) nm. The scale is realized based on a tunable-laser coupled integrating sphere source using galvanometer-driven mirror, and a silicon trap reference standard detector calibrated directly against NIM’s primary standard for spectral power responsivity and NIM’s effective area calibration facility for apertrue area. Sources and transfer standards are characterized, and spectral radiance responsivity can be measured with uncertainties at the (0.2∼0.4) % level.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-10-01
DOI
https://doi.org/10.1088/1742-6596/2864/1/012002
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Realization of (400∼950) nm detector-based spectral radiance scale at NIM

Yandong Lin, Wende Liu, Zhiwei Liu, Weiqiang Zhao et al.
Journal of Physics Conference Series
Calibration and Measurement Techniques
article

Realization of (400∼950) nm detector-based spectral radiance scale at NIM

Yandong Lin, Wende Liu, Zhiwei Liu, Weiqiang Zhao, Nan Xu, Haiyong Gan
article en

Abstract

Abstract Detector-based radiometric measurement is advantageous in terms of measurement uncertainty. National Institute of Metrology China (NIM) has developed a facility for detector-based spectral radiance scale realization in the range of (400∼950) nm. The scale is realized based on a tunable-laser coupled integrating sphere source using galvanometer-driven mirror, and a silicon trap reference standard detector calibrated directly against NIM’s primary standard for spectral power responsivity and NIM’s effective area calibration facility for apertrue area. Sources and transfer standards are characterized, and spectral radiance responsivity can be measured with uncertainties at the (0.2∼0.4) % level.

Journal of Physics Conference SeriesVol. 2864(1)
National Institute of Metrology (CN)
Openalex Percentile: Top 71%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.