Research on the Technology of Improving the Compatibility of DC Measurement Devices Based on the Operation Experience of Siemens Hardware Solutions

The aim of this study was to manufacture alternative Siemens DC measurement system equipment to solve the problems of increased failure rates of foreign DC measurement equipment and the stopped production of key parts. In this paper, the overall structure and common faults of the Siemens DC measurement system are introduced, the difference between TDM signal frame structure and FT3 frame structure is detailed, and the related functional structure, chip type, and function of the Siemens distal module and merging unit (including laser function) are studied. The remote module, merging unit (including laser function), and related hardware design and software design to replace the Siemens DC measurement system were developed, and the test environment and control protection, fault recording wave for communication, and other functional tests were built. The test results show that the domestic remote module, merging unit (laser function), and other technologies communicate normally with the existing Siemens and the domestic mainstream manufacturers, and the accuracy meets the requirements of the 0.2 level.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-10-25
DOI
https://doi.org/10.3390/electronics13214194
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Technology of Improving the Compatibility of DC Measurement Devices Based on the Operation Experience of Siemens Hardware Solutions

Yang Bai, Hao Li, Botao Ding, Xincui Tian et al.
Electronics
Smart Grid and Power Systems
article

Research on the Technology of Improving the Compatibility of DC Measurement Devices Based on the Operation Experience of Siemens Hardware Solutions

Yang Bai, Hao Li, Botao Ding, Xincui Tian, Zicong Zhang, Chao Liu, Yong Zheng
article en

Abstract

The aim of this study was to manufacture alternative Siemens DC measurement system equipment to solve the problems of increased failure rates of foreign DC measurement equipment and the stopped production of key parts. In this paper, the overall structure and common faults of the Siemens DC measurement system are introduced, the difference between TDM signal frame structure and FT3 frame structure is detailed, and the related functional structure, chip type, and function of the Siemens distal module and merging unit (including laser function) are studied. The remote module, merging unit (including laser function), and related hardware design and software design to replace the Siemens DC measurement system were developed, and the test environment and control protection, fault recording wave for communication, and other functional tests were built. The test results show that the domestic remote module, merging unit (laser function), and other technologies communicate normally with the existing Siemens and the domestic mainstream manufacturers, and the accuracy meets the requirements of the 0.2 level.

ElectronicsVol. 13(21)
Kunming University of Science and Technology (CN)
National Natural Science Foundation of China
Industry, innovation and infrastructure
Openalex Percentile: Top 83%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.