Split G-Quadruplex Programmed Recyclable AIE-Biosensor for Label-Free Detection of miRNA in Acute Kidney Injury

We herein rationally designed a target-recyclable AIE-biosensor based on a split G-quadruplex for label-free detection of miRNA in acute kidney injury. Initially, the PG was in an "OFF" state, and the two split segments (G4-a and G4-b) of G4 were tethered at the two terminals of P1 and far away from each other due to the rigid duplex structure formed by the partially complementary intermediate sequences of P2 and P1, bringing MG with quenched fluorescence. In the presence of target, the 5'-PO<sub>4</sub> P2 was displaced from PG probe and competitively hybridized with target, which led to G4-a and G4-b tending to form an intact intermolecular G-quadruplex, providing sites for MG intercalation, thus generating an activated "ON" fluorescence signal due to the restriction of intermolecular motion. Successively, relying on the λ-exonuclease (λ-Exo) cleavage reaction-assisted target recycling, more amounts of targets will be liberated, accompanied by forming more G-quadruplex and binding more MG, resulting in a strong fluorescence signal, further realizing the sensitive detection of the targets. As a proof of concept, miRNA-21 was chosen as the model target. Endowing with the precise target recognition and efficient cleavage activity of λ-Exo, the AIE-biosensor exhibited excellent detection sensitivity and specificity, which could quantitatively detect miRNA-21 down to 10.36 fM with a single mismatch specificity. The results revealed that the distinctive attributes of noninvasive, simple, and efficient in this G-quadruplex-based AIE-biosensor offered promising prospects for extensive applications in AKI screening and early clinical diagnosis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-25
DOI
https://doi.org/10.1021/acs.analchem.4c04228
Citations
11
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Split G-Quadruplex Programmed Recyclable AIE-Biosensor for Label-Free Detection of miRNA in Acute Kidney Injury

Jinyan Li, Tingfei Xie, Xiaolu Sui, Pengfei Zhang et al.
11 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
2.57
article

Split G-Quadruplex Programmed Recyclable AIE-Biosensor for Label-Free Detection of miRNA in Acute Kidney Injury

Jinyan Li, Tingfei Xie, Xiaolu Sui, Pengfei Zhang, Jihong Chen, Zhi‐Tao Wang, Wenjie Ma
article en
11 citations

Abstract

We herein rationally designed a target-recyclable AIE-biosensor based on a split G-quadruplex for label-free detection of miRNA in acute kidney injury. Initially, the PG was in an "OFF" state, and the two split segments (G4-a and G4-b) of G4 were tethered at the two terminals of P1 and far away from each other due to the rigid duplex structure formed by the partially complementary intermediate sequences of P2 and P1, bringing MG with quenched fluorescence. In the presence of target, the 5'-PO<sub>4</sub> P2 was displaced from PG probe and competitively hybridized with target, which led to G4-a and G4-b tending to form an intact intermolecular G-quadruplex, providing sites for MG intercalation, thus generating an activated "ON" fluorescence signal due to the restriction of intermolecular motion. Successively, relying on the λ-exonuclease (λ-Exo) cleavage reaction-assisted target recycling, more amounts of targets will be liberated, accompanied by forming more G-quadruplex and binding more MG, resulting in a strong fluorescence signal, further realizing the sensitive detection of the targets. As a proof of concept, miRNA-21 was chosen as the model target. Endowing with the precise target recognition and efficient cleavage activity of λ-Exo, the AIE-biosensor exhibited excellent detection sensitivity and specificity, which could quantitatively detect miRNA-21 down to 10.36 fM with a single mismatch specificity. The results revealed that the distinctive attributes of noninvasive, simple, and efficient in this G-quadruplex-based AIE-biosensor offered promising prospects for extensive applications in AKI screening and early clinical diagnosis.

Analytical ChemistryVol. 96(44)
Chinese Academy of Sciences (CN), Hunan Institute of Engineering (CN), Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES), Shenzhen Institutes of Advanced Technology (CN), Shenzhen Second People's Hospital (CN)
Education Department of Hunan Province, Chinese Academy of Sciences, Natural Science Foundation of Hunan Province
Good health and well-being
Openalex Percentile: Top 10%
Advanced biosensing and bioanalysis techniques
2.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.