AAPM task group report 135.B: Quality assurance for robotic radiosurgery

AAPM Task Group Report 135.B covers new technology components that have been added to an established radiosurgery platform and updates the components that were not well covered in the previous report. Considering the current state of the platform, this task group (TG) is a combination of a foundational task group to establish the basis for new processes/technology and an educational task group updating guidelines on the established components of the platform. Because the technology discussed in this document has a relatively small user base compared to C-arm isocentric linacs, the authors chose to emphasize the educational components to assist medical physicists who are new to the technology and have not had the opportunity to receive in-depth vendor training at the time of reading this report. The TG has developed codes of practice, introduced QA, and developed guidelines which are generally expected to become enduring practice. This report makes prescriptive recommendations as there has not been enough longitudinal experience with some of the new technical components to develop a data-based risk analysis.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2024-10-25
DOI
https://doi.org/10.1002/mp.17478
Citations
6
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AAPM task group report 135.B: Quality assurance for robotic radiosurgery

Jeffrey A. Garrett, M Noll, Alan Cohen, Christoph Füerweger et al.
6 citations
Medical Physics
Advanced Radiotherapy Techniques
3.65
article

AAPM task group report 135.B: Quality assurance for robotic radiosurgery

Jeffrey A. Garrett, M Noll, Alan Cohen, Christoph Füerweger, Ellen E. Wilcox, Martina Descovich, Sonja Dieterich, Anand Prabhu, David D. Taylor, Lei Wang, Jun Yang
article en
6 citations

Abstract

AAPM Task Group Report 135.B covers new technology components that have been added to an established radiosurgery platform and updates the components that were not well covered in the previous report. Considering the current state of the platform, this task group (TG) is a combination of a foundational task group to establish the basis for new processes/technology and an educational task group updating guidelines on the established components of the platform. Because the technology discussed in this document has a relatively small user base compared to C-arm isocentric linacs, the authors chose to emphasize the educational components to assist medical physicists who are new to the technology and have not had the opportunity to receive in-depth vendor training at the time of reading this report. The TG has developed codes of practice, introduced QA, and developed guidelines which are generally expected to become enduring practice. This report makes prescriptive recommendations as there has not been enough longitudinal experience with some of the new technical components to develop a data-based risk analysis.

Medical PhysicsVol. 52(1)
University of California, San Francisco (US), Riverview Medical Center (US), Accuray (United States) (US), Grand Junction VA Medical Center (US), Hackensack Meridian Health (US), University of California Davis Medical Center (US), Varian Medical Systems (United States) (US), Stanford University (US)
Quality Education
Openalex Percentile: Top 7%
Advanced Radiotherapy Techniques
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.