Validation of the Physical Random Unintentional Radiation Model by Measurement of an Artificial Test Object in an Anechoic Chamber

The purpose of this paper is to present the metrological investigation of the normative emission measurement methods to validate the results of the stochastic radiator model and to derive practical recommendations for the applicable measurement methods in the frequency range from 6 GHz to 40 GHz. An artificial test object was chosen to simulate the characteristics of an unintentional radiator. Emission values measured in the anechoic chamber with high angular resolution are used as the basis for the evaluation. The results reveal a strong dependence of the detected maximum on the angular resolution used, with deviations reaching up to 11 dB. To improve reproducibility and reduce uncertainty of the normative methods, a statistical approach is suggested to reduce measurement time.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/emceurope59828.2024.10722328
Citations
2
Primary Topic
Graphite, nuclear technology, radiation studies
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of the Physical Random Unintentional Radiation Model by Measurement of an Artificial Test Object in an Anechoic Chamber

Ralf Vick, Max Rosenthal, Jörg Petzold
2 citations
Graphite, nuclear technology, radiation studies
0.23
article

Validation of the Physical Random Unintentional Radiation Model by Measurement of an Artificial Test Object in an Anechoic Chamber

Ralf Vick, Max Rosenthal, Jörg Petzold
article en
2 citations

Abstract

The purpose of this paper is to present the metrological investigation of the normative emission measurement methods to validate the results of the stochastic radiator model and to derive practical recommendations for the applicable measurement methods in the frequency range from 6 GHz to 40 GHz. An artificial test object was chosen to simulate the characteristics of an unintentional radiator. Emission values measured in the anechoic chamber with high angular resolution are used as the basis for the evaluation. The results reveal a strong dependence of the detected maximum on the angular resolution used, with deviations reaching up to 11 dB. To improve reproducibility and reduce uncertainty of the normative methods, a statistical approach is suggested to reduce measurement time.

Otto-von-Guericke-Universität Magdeburg (DE)
Reduced inequalities
Openalex Percentile: Top 50%
Graphite, nuclear technology, radiation studies
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.