Evaluation of Absorber Loading Effect on the Maximum Field Strength in an MRI Room

This paper evaluates the absorber loading effect on the maximum expected field strength variability in a 30 m3 MRI room. Loading an MRI room modifies two relevant parameters of the EMFs. First, adding RF absorbers reduces the variability of the maximum field strength. This improves the predictability of the EMFs generated in the room. Second, adding RF absorbers also introduces attenuation losses, which reduces the field strength. This reduction decreases the risk of generating unintentional electromagnetic interference. The field variability is evaluated through the average and minimal insertion loss of the room. The results reveal the difference in loss distribution between the MRI room and a VIRC, which acts as a reference electromagnetic environment. This reference is used to define the minimum amount of losses required to increase the IL of the MRI room. Additionally, the Q-factor of the MRI room is presented, which strengthens previous research findings, suggesting that an MRI room is similar to a heavily loaded reverberation chamber. These results are significant as reverberation chambers are rarely used to design MRIcompatible test setups.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/emceurope59828.2024.10722656
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Absorber Loading Effect on the Maximum Field Strength in an MRI Room

Simón Rendón Vélez, Rıdvan Aba, Robert Vogt-Ardatjew, Frank Leferink et al.
Engineering Applied Research
article

Evaluation of Absorber Loading Effect on the Maximum Field Strength in an MRI Room

Simón Rendón Vélez, Rıdvan Aba, Robert Vogt-Ardatjew, Frank Leferink, Bärbel van den Berg, Mark van Helvoort
article en

Abstract

This paper evaluates the absorber loading effect on the maximum expected field strength variability in a 30 m3 MRI room. Loading an MRI room modifies two relevant parameters of the EMFs. First, adding RF absorbers reduces the variability of the maximum field strength. This improves the predictability of the EMFs generated in the room. Second, adding RF absorbers also introduces attenuation losses, which reduces the field strength. This reduction decreases the risk of generating unintentional electromagnetic interference. The field variability is evaluated through the average and minimal insertion loss of the room. The results reveal the difference in loss distribution between the MRI room and a VIRC, which acts as a reference electromagnetic environment. This reference is used to define the minimum amount of losses required to increase the IL of the MRI room. Additionally, the Q-factor of the MRI room is presented, which strengthens previous research findings, suggesting that an MRI room is similar to a heavily loaded reverberation chamber. These results are significant as reverberation chambers are rarely used to design MRIcompatible test setups.

Medisch Spectrum Twente (NL), Philips (Netherlands) (NL), University of Twente (NL)
European Commission
Affordable and clean energy
Openalex Percentile: Top 79%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.