Origin of the Damped Oscillatory Waves in the MV Mains of the High Current Testing Laboratory

The High Current Testing Laboratory (HCTL) must be safe for the operational staff. Moreover, the equipment supervising the test must operate without any malfunctions. Relevant elements of the setup in the HCTLs are a three-phase 15 kV supply source, a medium voltage (MV) circuit breaker (CB), a three-phase supply line, a medium voltage/low voltage (MV/LV) transformer and a short circuit switch in the circuit at the secondary side of the transformer. The time-phase controller used for supervising the test in the HCTL under consideration is observed to get sporadically out of control by switching ON the MV CB. Unexpectedly, it starts the test immediately, i.e., it closes the short circuit switch without the operator’s release. It was reported in previous publications of the authors that repetitive Damped Oscillatory Waves (DOW) cause malfunctioning of the time-phase controller. However, answering the question about the origin of the DOWs and the number of DOWs is elaborated only in this paper, using numerical simulation of the transients in the MV supply line. In the paper, a numerical model of the three-phase circuit is presented. Transients that follow closing of the MW CB are simulated. Numerical simulations confirm that the origin of DOWs is the closing of the MV CB, and the repetition of DOW is due to different instances of closing the switch in each phase.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/emceurope59828.2024.10722288
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Origin of the Damped Oscillatory Waves in the MV Mains of the High Current Testing Laboratory

Jolanta Sadura, Jan Sroka, Jacek Starzyński
Oil and Gas Production Techniques
article

Origin of the Damped Oscillatory Waves in the MV Mains of the High Current Testing Laboratory

Jolanta Sadura, Jan Sroka, Jacek Starzyński
article en

Abstract

The High Current Testing Laboratory (HCTL) must be safe for the operational staff. Moreover, the equipment supervising the test must operate without any malfunctions. Relevant elements of the setup in the HCTLs are a three-phase 15 kV supply source, a medium voltage (MV) circuit breaker (CB), a three-phase supply line, a medium voltage/low voltage (MV/LV) transformer and a short circuit switch in the circuit at the secondary side of the transformer. The time-phase controller used for supervising the test in the HCTL under consideration is observed to get sporadically out of control by switching ON the MV CB. Unexpectedly, it starts the test immediately, i.e., it closes the short circuit switch without the operator’s release. It was reported in previous publications of the authors that repetitive Damped Oscillatory Waves (DOW) cause malfunctioning of the time-phase controller. However, answering the question about the origin of the DOWs and the number of DOWs is elaborated only in this paper, using numerical simulation of the transients in the MV supply line. In the paper, a numerical model of the three-phase circuit is presented. Transients that follow closing of the MW CB are simulated. Numerical simulations confirm that the origin of DOWs is the closing of the MV CB, and the repetition of DOW is due to different instances of closing the switch in each phase.

Warsaw University of Technology (PL)
Openalex Percentile: Top 76%
Oil and Gas Production Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.