Field Strength Check Standard Probe Comparisons to Historical Measurements

The National Institute of Standards and Technology (NIST) in Boulder, CO, USA provides measurements of radio frequency field probes in a standard field. This service provides calibrations to industry and other government agencies, and performs inter-comparisons with other national metrology institutes. Check standard probes are periodically measured to maintain the consistency of the standard fields used for calibration. The NIST field strength calibration service was greyed-out from 2014 to 2021 for renovations. After the renovation, measurements of check standards were performed and compared with historical data. Here we demonstrate equivalence of generated fields at the NIST facility from 1996 to 2024 across the frequency range 900 MHz to 10 GHz from 6 three-axis check standard probes.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/emceurope59828.2024.10722231
Primary Topic
Electrostatic Discharge in Electronics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field Strength Check Standard Probe Comparisons to Historical Measurements

William J. Watterson, Lucas Koepke, Christopher L. Holloway, Matthew T. Simons et al.
Electrostatic Discharge in Electronics
article

Field Strength Check Standard Probe Comparisons to Historical Measurements

William J. Watterson, Lucas Koepke, Christopher L. Holloway, Matthew T. Simons, Vincent Neylon, Chris Parks
article en

Abstract

The National Institute of Standards and Technology (NIST) in Boulder, CO, USA provides measurements of radio frequency field probes in a standard field. This service provides calibrations to industry and other government agencies, and performs inter-comparisons with other national metrology institutes. Check standard probes are periodically measured to maintain the consistency of the standard fields used for calibration. The NIST field strength calibration service was greyed-out from 2014 to 2021 for renovations. After the renovation, measurements of check standards were performed and compared with historical data. Here we demonstrate equivalence of generated fields at the NIST facility from 1996 to 2024 across the frequency range 900 MHz to 10 GHz from 6 three-axis check standard probes.

National Institute of Standards and Technology (US), University of Colorado Boulder (US), Communications Technology Laboratory (US)
Climate action
Openalex Percentile: Top 83%
Electrostatic Discharge in Electronics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Field Strength Check Standard Probe Comparisons to Historical Measurements — William J. Watterson, Lucas Koepke, et al. · (2024) | TGRS Research Map | TGRS