A SDR-Based Inside-Out in-situ Shielding Effectiveness Measurement Technique

In this study a shielding effectiveness (SE) measurement procedure is presented, utilizing a small footprint software-defined radio (SDR) device that enables the realization of a spectrum analysis of medium-sized cavities in-situ. It additionally makes use of a standalone reference radiator, enabling an inside-out measurement procedure to be executed. Because of this, no physical link exists between the inside of the enclosure and the outside, guarantying a reduction of possible coupling paths and removing the necessity to physically alter the enclosures original design. This technique was experimentally validated using a standard commercial-of-the-shelf (COTS) 19 -inch cabinet, in which two antenna configurations were considered, in both position and polarization, enabling a performance assessment when in-situ restrictions need to be considered.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/emceurope59828.2024.10722750
Citations
2
Primary Topic
Electromagnetic Compatibility and Measurements
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A SDR-Based Inside-Out in-situ Shielding Effectiveness Measurement Technique

Hans Schipper, Rıdvan Aba, Robert Vogt-Ardatjew, Frank Leferink et al.
2 citations
Electromagnetic Compatibility and Measurements
0.42
article

A SDR-Based Inside-Out in-situ Shielding Effectiveness Measurement Technique

Hans Schipper, Rıdvan Aba, Robert Vogt-Ardatjew, Frank Leferink, Miguel Figueirinhas
article en
2 citations

Abstract

In this study a shielding effectiveness (SE) measurement procedure is presented, utilizing a small footprint software-defined radio (SDR) device that enables the realization of a spectrum analysis of medium-sized cavities in-situ. It additionally makes use of a standalone reference radiator, enabling an inside-out measurement procedure to be executed. Because of this, no physical link exists between the inside of the enclosure and the outside, guarantying a reduction of possible coupling paths and removing the necessity to physically alter the enclosures original design. This technique was experimentally validated using a standard commercial-of-the-shelf (COTS) 19 -inch cabinet, in which two antenna configurations were considered, in both position and polarization, enabling a performance assessment when in-situ restrictions need to be considered.

University of Twente (NL)
UK Research and Innovation, European Commission, Horizon 2020
Openalex Percentile: Top 37%
Electromagnetic Compatibility and Measurements
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.