Improved Limited-View Ultrasound Tomography via Machine Learning

Tomographic reconstruction is used extensively in medicine, nondestructive testing (NDT), and geology. In an ideal situation, where measurements are taken at all angles around an object, known as full-view configuration, a full reconstruction of the object can be produced. One of the major issues faced in tomographic imaging is when measurements cannot be taken freely around the object under inspection. This may be caused by the size and geometry of the object or difficulty accessing from particular directions. The resulting limited view (LV) transducer configuration leads to a large deterioration in image quality; thus, it is very beneficial to employ a compensation algorithm. At present, the most effective compensation algorithms require a large amount of computing power or a bespoke case-by-case approach, often with numerous arbitrary constants which must be tuned for a specific application. This work proposes a machine learning (ML)-based approach to perform the LV compensation. The model is based around an autoencoder (AE) architecture. It is trained on an artificial dataset, taking advantage of the ability to generate arbitrary LV images given a full view input. The approach is evaluated on ten laser-scanned corrosion maps and the results compared to positivity regularization-a LV compensation algorithm similar in the speed of execution and generalization potential. The algorithms are compared for root mean squared error (RMSE) across the image and maximum absolute error (MAE). Furthermore, they are visually compared for subjective quality. Compared to the conventional algorithm, the ML-based approach improves on the MAE in eight out of the ten cases. The conventional approach performs better on mean RMSE, which is explained by the ML outputting an inaccurate background level, which is not a critical ability. Most importantly, the visual inspection of outputs shows the ML approach reconstructs the images better, especially in the case of irregular corrosion patches. Compared to LV images, the ML method improves both the RMSE and MAE by 41%.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-10-25
DOI
https://doi.org/10.1109/tuffc.2024.3486668
Citations
1
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Limited-View Ultrasound Tomography via Machine Learning

Stefano Mariani, Peter Huthwaite, Mikolaj Mroszczak
1 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Radiomics and Machine Learning in Medical Imaging
0.40
article

Improved Limited-View Ultrasound Tomography via Machine Learning

Stefano Mariani, Peter Huthwaite, Mikolaj Mroszczak
article en
1 citations

Abstract

Tomographic reconstruction is used extensively in medicine, nondestructive testing (NDT), and geology. In an ideal situation, where measurements are taken at all angles around an object, known as full-view configuration, a full reconstruction of the object can be produced. One of the major issues faced in tomographic imaging is when measurements cannot be taken freely around the object under inspection. This may be caused by the size and geometry of the object or difficulty accessing from particular directions. The resulting limited view (LV) transducer configuration leads to a large deterioration in image quality; thus, it is very beneficial to employ a compensation algorithm. At present, the most effective compensation algorithms require a large amount of computing power or a bespoke case-by-case approach, often with numerous arbitrary constants which must be tuned for a specific application. This work proposes a machine learning (ML)-based approach to perform the LV compensation. The model is based around an autoencoder (AE) architecture. It is trained on an artificial dataset, taking advantage of the ability to generate arbitrary LV images given a full view input. The approach is evaluated on ten laser-scanned corrosion maps and the results compared to positivity regularization-a LV compensation algorithm similar in the speed of execution and generalization potential. The algorithms are compared for root mean squared error (RMSE) across the image and maximum absolute error (MAE). Furthermore, they are visually compared for subjective quality. Compared to the conventional algorithm, the ML-based approach improves on the MAE in eight out of the ten cases. The conventional approach performs better on mean RMSE, which is explained by the ML outputting an inaccurate background level, which is not a critical ability. Most importantly, the visual inspection of outputs shows the ML approach reconstructs the images better, especially in the case of irregular corrosion patches. Compared to LV images, the ML method improves both the RMSE and MAE by 41%.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(12: Breaking the Resolution)
Imperial College London (GB), University of Bologna (IT)
Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 33%
Radiomics and Machine Learning in Medical Imaging
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.