Plantar Planar Dual-Array Electrical Impedance Tomography (PPDA-EIT) Method for Early Diabetic Foot Ulcers’ Detection

The relationship between impedance and the concentrations of glucose and L-tyrosine (TYR) has been clarified by the plantar planar dual-array electrical impedance tomography (PPDA-EIT) for early detection of diabetic foot ulcers (DFUs). PPDA-EIT images the electrical response changes of glucose and L-TYR at different concentrations in the DFU environment. In the experiments, the characteristic frequency was determined at the maximum impedance difference (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta $ </tex-math></inline-formula>Z) by the electrochemical impedance spectroscopy (EIS) method. Optimal sensor location and size were determined based on analyzing the pressure concentration area during gait. The optimum electrode size and excitation method were found through 3-D electromagnetic simulation. Pork-mimic experiments were conducted to validate the sensor design by evaluating the image correlation coefficient (ICC) and the root mean square error (RMSE). From the EIS experimental results, glucose and L-TYR, as biomarkers for early DFUs’ detection, produced the largest impedance difference (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta $ </tex-math></inline-formula>Z) at a measurement frequency of 1 MHz. From the 3-D electromagnetic simulation results, the most effective excitation involved the central electrode (sixth electrode), with the optimal electrode being a square with a side length of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${D} = 8$ </tex-math></inline-formula> mm. The PPDA-EIT sensor was able to satisfactorily obtain reconstrued images of the object with an optimal ICC =0.8110 and RMSE =0.0982, which suggests that the approach used in this study provides an accurate indication of the glucose and L-TYR concentration change region in early DFUs.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-10-25
DOI
https://doi.org/10.1109/jsen.2024.3483935
Citations
2
Primary Topic
Diabetic Foot Ulcer Assessment and Management
Type
article
Field-Weighted Citation Impact
0.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plantar Planar Dual-Array Electrical Impedance Tomography (PPDA-EIT) Method for Early Diabetic Foot Ulcers’ Detection

Songpei Hu, Bo Sun, Hui Feng, Jiafeng Yao et al.
2 citations
IEEE Sensors Journal
Diabetic Foot Ulcer Assessment and Management
0.72
article

Plantar Planar Dual-Array Electrical Impedance Tomography (PPDA-EIT) Method for Early Diabetic Foot Ulcers’ Detection

Songpei Hu, Bo Sun, Hui Feng, Jiafeng Yao, Tong Zhao, Yunqian Wang, Yuru Bai
article en
2 citations

Abstract

The relationship between impedance and the concentrations of glucose and L-tyrosine (TYR) has been clarified by the plantar planar dual-array electrical impedance tomography (PPDA-EIT) for early detection of diabetic foot ulcers (DFUs). PPDA-EIT images the electrical response changes of glucose and L-TYR at different concentrations in the DFU environment. In the experiments, the characteristic frequency was determined at the maximum impedance difference (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta $ </tex-math></inline-formula>Z) by the electrochemical impedance spectroscopy (EIS) method. Optimal sensor location and size were determined based on analyzing the pressure concentration area during gait. The optimum electrode size and excitation method were found through 3-D electromagnetic simulation. Pork-mimic experiments were conducted to validate the sensor design by evaluating the image correlation coefficient (ICC) and the root mean square error (RMSE). From the EIS experimental results, glucose and L-TYR, as biomarkers for early DFUs’ detection, produced the largest impedance difference (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta $ </tex-math></inline-formula>Z) at a measurement frequency of 1 MHz. From the 3-D electromagnetic simulation results, the most effective excitation involved the central electrode (sixth electrode), with the optimal electrode being a square with a side length of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${D} = 8$ </tex-math></inline-formula> mm. The PPDA-EIT sensor was able to satisfactorily obtain reconstrued images of the object with an optimal ICC =0.8110 and RMSE =0.0982, which suggests that the approach used in this study provides an accurate indication of the glucose and L-TYR concentration change region in early DFUs.

IEEE Sensors JournalVol. 24(23)
Second Affiliated Hospital of Xi'an Jiaotong University (CN), Xi'an University of Technology (CN), Nanjing Jiangning Hospital (CN), Nanjing Medical University (CN), Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 24%
Diabetic Foot Ulcer Assessment and Management
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.