A Fully Printable and Integrated System with Long-Term Stability for Versatile and Multimodal Perspiration Tracking

Real-time and continuous monitoring of physiological status via noninvasive sweat sensing shows promise for personalized healthcare and fitness management. However, the largely varied perspiration rates in different body statuses introduce challenges for effective sweat collection and accurate sensing. Herein, a fully printable strategy was developed to realize fully integrated patches for wireless sensing of sweat biomarker levels and perspiration rates with desirable stability and versatility. The printable calcium sensors with modified ion-selective membranes displayed an ultrawide linear range of 0.1-100 mM and a long-term stability with minimized drift down to 0.083 mV/h for around 40 h. Moreover, the microfluidic channels in versatile configurations were capable of a minimum sweat rate monitoring of 0.5 μL/min and a large sweat storage volume of up to 200 μL. The as-proposed fully printable sensing platforms provide high compatibility for sensor integration to achieve versatile perspiration tracking and comprehensive health monitoring.

Authors

Institutions

Publication Details

Journal
Nano Letters
Published
2024-10-25
DOI
https://doi.org/10.1021/acs.nanolett.4c04328
Citations
6
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fully Printable and Integrated System with Long-Term Stability for Versatile and Multimodal Perspiration Tracking

Wenhao Ye, Yuanjing Lin, Xiaohao Ma, Kemeng Zhou et al.
6 citations
Nano Letters
Advanced Sensor and Energy Harvesting Materials
1.11
article

A Fully Printable and Integrated System with Long-Term Stability for Versatile and Multimodal Perspiration Tracking

Wenhao Ye, Yuanjing Lin, Xiaohao Ma, Kemeng Zhou, Zhiyong Fan, Jitao Huang, Liting Huang, Ruochen Ding, Zihan Zhou
article en
6 citations

Abstract

Real-time and continuous monitoring of physiological status via noninvasive sweat sensing shows promise for personalized healthcare and fitness management. However, the largely varied perspiration rates in different body statuses introduce challenges for effective sweat collection and accurate sensing. Herein, a fully printable strategy was developed to realize fully integrated patches for wireless sensing of sweat biomarker levels and perspiration rates with desirable stability and versatility. The printable calcium sensors with modified ion-selective membranes displayed an ultrawide linear range of 0.1-100 mM and a long-term stability with minimized drift down to 0.083 mV/h for around 40 h. Moreover, the microfluidic channels in versatile configurations were capable of a minimum sweat rate monitoring of 0.5 μL/min and a large sweat storage volume of up to 200 μL. The as-proposed fully printable sensing platforms provide high compatibility for sensor integration to achieve versatile perspiration tracking and comprehensive health monitoring.

Nano LettersVol. 24(47)
Hong Kong University of Science and Technology (HK), Southern University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 24%
Advanced Sensor and Energy Harvesting Materials
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.